Technical specifications

Rated motor power 15.0 kW typical (4-pole three-phase asynchronous motor)
Rated output current 32 A nominal at 8 kHz switching frequency
Max. output current 48 A for 60 s (1 min overload at Imax / 2 min base load at 75% Ir)
Supply voltage 3/PE AC 320 V -0% … 550 V +0%; 45 … 65 Hz
Operating temperature -10 … +50 °C (derated by 2.5%/°C above +40 °C)
Protection rating IP20
Built-in ports X3 control terminal strip (analog/digital I/O)
Communication expansion FIF slot for plug-in function modules (E82ZAF* family)

Description

The Lenze E82CV153K4B201 is a 15.0 kW 8200 vector frequency inverter built in cold-plate technology, where a bare metal cooling plate replaces the standard heatsink for connection to a customer-side cooler. Maintenance and procurement teams choose genuine surplus or refurbished units of this model because the cold-plate design remains available only on request, and Autronexa verifies each unit against OEM datasheet markings before it ships.

What the E82CV153K4B201 Does in an 8200 vector System

The 8200 vector family handles variable-speed control of three-phase asynchronous motors, and this variant is rated for a 15.0 kW typical four-pole motor. It provides V/f characteristic control in linear or quadratic mode plus sensorless vector control, with an output frequency range of -650 to +650 Hz. Rated output current is 32 A nominal at an 8 kHz switching frequency, while the 48 A maximum output current holds for 60 s in a periodic load cycle of one minute overload at Imax followed by two minutes base load at 75% Ir. An integrated brake transistor and the X3 control terminal strip with analog and digital I/O are built in. No fieldbus protocol is built in; the FIF slot accepts E82ZAF* plug-in function modules when network communication is required.

Figure 1: Front view of the Lenze E82CV153K4B201 Replaced by a bare metal cooling plate connected to a separate customer-side showing its physical design and enclosure.

Cold-Plate Thermal Data and Installation Checks

Because the heatsink is replaced by a cooling plate, thermal planning shifts to the customer-side cooler. The dissipated power loss is 410 W, thermal resistance between cooler and cooling medium is Rth ≤ 0.085 K/W, and the maximum permissible cooling-plate temperature is 75 °C. The supply accepts 3/PE AC 320 V -0% to 550 V +0% at 45 to 65 Hz. Operating temperature is -10 to +50 °C, derated by 2.5% per °C above +40 °C, and the IP20 rating suits cabinet installation. Storage temperature spans -25 to +60 °C, and relative humidity averages 85% RH without condensation. Before ordering, confirm your cooler can hold the plate below 75 °C under load.

Figure 2: Technical layout and connection details for the Lenze E82CV153K4B201 Replaced by a bare metal cooling plate connected to a separate customer-side.

Why Genuine Surplus Fits This Cold-Plate Variant

Lenze lists the 8200 vector among its previous products, and the cold-plate special design is available on request rather than as a standard catalogue item. That makes surplus and refurbished units a practical route for maintenance budgets, provided condition is verified. Autronexa checks each unit against OEM datasheet markings and part-number cross-reference, then functionally verifies it against the published specifications. Note that Lenze confirms no drop-in same-order-code replacement exists; the i950 with a PROFIBUS module and the L_ICIP library emulates 8200 vector behaviour as a migration path. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: E82CV153K4B201-datasheet.pdf

Frequently asked questions

Is this E82CV153K4B201 a genuine Lenze unit or a clone?

Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before listing it. The E82CV153K4B201 is supplied as a genuine Lenze 8200 vector cold-plate inverter, and we can share verification details on request.

What condition will the E82CV153K4B201 arrive in?

Our default supply condition is refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask Autronexa to confirm the grading of the specific unit reserved for your order.

How fast can Autronexa ship the E82CV153K4B201?

Lead time depends on the unit reserved for your order. Contact Autronexa with your part number for current lead time and availability; surplus and refurbished stock is ready to ship once verified.

Does the E82CV153K4B201 include a fieldbus protocol?

No fieldbus protocol is built in. Communication expansion uses the FIF slot for E82ZAF* plug-in function modules, so confirm the required module and cabling with your supplier before integration.

Related & compatible parts

Lenze

E82CV551K2C

Genuine surplus Lenze E82CV551K2C cold-plate inverter: 0.55 kW, 3.0 A, IP20, verified condition and practical sourcing support.

In Stock

Lenze

ERBP027R200W

Genuine surplus Lenze ERBP027R200W brake resistor: 27 Ω, 200 W continuous braking, 800 V DC maximum, with integrated…

In Stock

Lenze

E94ASHE0864

Genuine surplus Lenze E94ASHE0864 axis module: 45 kW, 86 A rated output, CANopen onboard, IP20. Verified condition and…

Quote on request

Lenze

E82CV152K2C

Genuine surplus Lenze E82CV152K2C cold-plate inverter, 1.5 kW, verified condition and ready to ship from Autronexa.

In Stock

News & guides for Lenze

View all articles

Request a quote for this part

Part number: E82CV153K4B201

We reply within one business day.

E82CV153K4B201 Quote reply within 1 business day