Keyence Vibration Monitoring GL-V series
Keyence GL-VM30LN
Vibration Monitoring
Small & robust metal Type 4 safety light curtain, body protection type, 30 beam axes, NPN output, 1200 mm total length.
- New Surplus
- Available on request
Availability & pricing
| Condition | Price | Stock / lead time | Action |
|---|---|---|---|
| New Surplus | On request | Available on request |
Ships within 7 business days
Technical specifications
| Model | GL-VM30LN |
|---|---|
| Brand | Keyence |
| Series | GL-V series |
| Safety light curtain | Transmitter + Receiver set (Type 4 ESPE / AOPD) |
| Synchronization | Optical synchronization |
| Light source | Infrared LED (850 nm), Exempt Group (IEC62471) |
| Effective angular aperture | up to ±2.5° (at 3 m or above) |
| Detection mode | ON when all beam axes are received |
| Interference prevention | up to 2 units by series connection and switch setting |
| Protection type | Body protection |
| Minimum detectable object size | ø45 mm |
| Number of beam axes | 30 |
| Beam axis spacing | 40 mm |
| Detection height | 1160 mm |
| Total length | 1200 mm |
| Detecting distance | 0.3 to 15 m |
| Response time (OSSD, channel 0, ON→OFF) | max. 5.1 ms |
| Built-in ports | None |
| Protocols | None |
| Communication expansion | None |
| Supply voltage | 24 VDC -20/+25%, ripple (P-P) 10% or less, Class 2 |
| Maximum load current | 150 mA or less |
| Residual voltage (ON) | up to 2.5 V (5 m cable); OFF voltage: up to 2.0 V (5 m cable) |
| Leakage current | up to 0.8 mA; max. load capacity: 0.8 µF; load wiring resistance: up to 2.5 Ω |
| Inputs | short-circuit current approx. 3 mA |
| Safety standards | IEC61496-1/-2 (Type 4 ESPE/AOPD), EN ISO13849-1 (Category 4, PL e), IEC61508 (SIL3), UL60947-1 / CSA C22.2 No.60947-1, UL1998 |
| EMC | IEC/EN61496-1, EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
| Protection circuit | Supply reverse-connection, per-output short-circuit and surge protection |
| Current consumption (indicator ON) | Transmitter max. 128 mA; Receiver max. 142 mA (OSSD output current not included) |
| Control output (OSSD) | Transistor output x2 (NPN) |
| Operating temperature | -30 to +55 °C (No freezing) |
| Storage temperature | -30 to +70 °C (No freezing) |
| Relative humidity | up to 95 % RH (no condensation) |
| Ambient light | Incandescent lamp 3,000 lux or less; Sunlight 20,000 lux or less |
| Protection rating | IP65/IP67 (IEC60529) |
| Overvoltage category | II |
| Vibration resistance | 5 to 150 Hz, 1G, 10 cycles each in X/Y/Z |
| Shock resistance | 15 G, 6 ms pulses, 100 times each in X/Y/Z |
| Material | Main unit Aluminum alloy; upper/lower case PPS (GF40%); front cover Polycarbonate, SUS304 |
| Dimensions (H×W×D) | Not available |
| Weight | Transmitter 780 g; Receiver 790 g |
Description
The GL-VM30LN is a catalog part supplied for replacement and new-build use in industrial control installations. Every rating below is taken from the manufacturer documentation for this part number. Headline figures: supply voltage 24 VDC -20/+25%, ripple (P-P) 10% or less, Class 2; weight Transmitter 780 g; Receiver 790 g; operating temperature -30 to +55 °C (No freezing)
Electrical Ratings
Supply voltage is 24 VDC -20/+25%, ripple (P-P) 10% or less, Class 2. match this against the supply available at the installation site, including any tolerance on the incoming feed. Maximum load current is 150 mA or less. confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Residual voltage (ON) is up to 2.5 V (5 m cable); OFF voltage: up to 2.0 V (5 m cable). match this against the supply available at the installation site, including any tolerance on the incoming feed. Leakage current is up to 0.8 mA; max. load capacity: 0.8 µF; load wiring resistance: up to 2.5 Ω. confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Current consumption (indicator ON) is Transmitter max. 128 mA; Receiver max. 142 mA (OSSD output current not included). confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Control output (OSSD) is Transistor output x2 (NPN). compare this against the requirement it must satisfy in the application before release to site. Overvoltage category is II. match this against the supply available at the installation site, including any tolerance on the incoming feed. Vibration resistance is 5 to 150 Hz, 1G, 10 cycles each in X/Y/Z. confirm the installed location falls within this environmental capability. Shock resistance is 15 G, 6 ms pulses, 100 times each in X/Y/Z. confirm the installed location falls within this environmental capability.
Mechanical & Dimensional Data
Minimum detectable object size is ø45 mm. take this measurement into account when setting panel depth, rail position or enclosure clearance, since oversize is the normal reason a correct part will not physically fit. Detection height is 1160 mm. take this measurement into account when setting panel depth, rail position or enclosure clearance, since oversize is the normal reason a correct part will not physically fit. Total length is 1200 mm. take this measurement into account when setting panel depth, rail position or enclosure clearance, since oversize is the normal reason a correct part will not physically fit. Material is Main unit Aluminum alloy; upper/lower case PPS (GF40%); front cover Polycarbonate, SUS304. the material determines corrosion behaviour and thermal performance in the installed environment. Weight is Transmitter 780 g; Receiver 790 g. factor this into lifting, rail-loading and shipping decisions; it is also the figure to quote when a handling study is required.
Environmental & Compliance Ratings
Interference prevention is up to 2 units by series connection and switch setting. use this to confirm the part is acceptable in the classified area of the installation, and to support the documentation in the plant safety file. Safety standards is IEC61496-1/-2 (Type 4 ESPE/AOPD), EN ISO13849-1 (Category 4, PL e), IEC61508 (SIL3), UL60947-1 / CSA C22.2 No.60947-1, UL1998. compare this against the requirement it must satisfy in the application before release to site. Operating temperature is -30 to +55 °C (No freezing). check the enclosure temperature at the planned mounting location stays inside this band during the hottest operating period. Storage temperature is -30 to +70 °C (No freezing). observe this figure during transport and warehouse storage, which are not the same condition as operation. Relative humidity is up to 95 % RH (no condensation). maintain the stated humidity range in the cabinet; condensation is the usual cause of failure in equipment installed in humid plant rooms. Ambient light is Incandescent lamp 3,000 lux or less; Sunlight 20,000 lux or less. check the enclosure temperature at the planned mounting location stays inside this band during the hottest operating period.
Signal & Communication
Response time (OSSD, channel 0, ON→OFF) is max. 5.1 ms. this defines what the part reads or drives; confirm it matches the transducer or signal source wired to it.
Additional Verified Data
Safety light curtain is Transmitter + Receiver set (Type 4 ESPE / AOPD). Synchronization is Optical synchronization. Light source is Infrared LED (850 nm), Exempt Group (IEC62471). Effective angular aperture is up to ±2.5° (at 3 m or above). Detection mode is ON when all beam axes are received. Protection type is Body protection. Number of beam axes is 30. Beam axis spacing is 40 mm. Detecting distance is 0.3 to 15 m. Inputs is short-circuit current approx. 3 mA. EMC is IEC/EN61496-1, EN55011 Class A, FCC Part15B Class A, ICES-003 Class A. Protection rating is IP65/IP67 (IEC60529).
Models in This Series
Autronexa currently lists this product entry as the only model in its entry. Cross-reference requests for equivalent or superseded part numbers are handled on request.
Confirming the Correct Variant Before Ordering
Read the part number marked on the unit being replaced and compare it character by character with the ordering code above, including any option suffix. Check the values in the technical specification table of this page against the nameplate on the existing unit rather than against a previous purchase record. Confirm the supply voltage available at the installation site is 24 VDC -20/+25%, ripple (P-P) 10% or less, Class 2, which is the documented requirement for this model.
Request a Quote
Autronexa supplies the GL-VM30LN as a quote-based item. Send the part number, quantity and destination for current stock, lead time and pricing; no fixed price is published for this part.
Frequently asked questions
What is the GL-VM30LN?
Keyence GL-VM30LN is an industrial automation component we supply from surplus and refurbished stock. Confirm the exact configuration, condition and lead time with our team before purchase.
Is the GL-VM30LN in stock, and what is the lead time?
We list the GL-VM30LN as in stock in New Surplus condition. Request a quote for current availability, pricing and confirmed lead time — most items ship within 1–3 business days.
Do you provide a datasheet for the GL-VM30LN?
Where available, the product page links the original manufacturer datasheet (PDF). Use the request-a-quote form to receive the full documentation pack and compliance information.
Can the GL-VM30LN be cross-referenced to an equivalent?
Many automation parts have equivalents or legacy replacements. Send us the GL-VM30LN together with your application details and we will confirm compatibility and alternatives.
What input voltage does the GL-VM30LN use?
The GL-VM30LN operates at 24 VDC -20/+25%, ripple (P-P) 10% or less, Class 2. Verify the exact range and any hazardous-area limits against the product label before installation, because input requirements vary by ordered variant.
What is the operating temperature range of the GL-VM30LN?
The GL-VM30LN operating temperature is listed as -30 to +55 °C (No freezing). Stay within the documented band during operation; storage limits may differ. Elevated ambient conditions can reduce the continuous current or power rating of the module.
What are the dimensions and weight of the GL-VM30LN?
The GL-VM30LN measures Not available and weighs Transmitter 780 g; Receiver 790 g. Confirm clearance and rack or panel space before ordering.
What is the GL-VM30LN and what is it used for?
The GL-VM30LN is a industrial component device. It is used in industrial control and automation systems where a verified part number and specification match are required for replacement or new design.
What supply voltage does the GL-VM30LN need?
The manufacturer documentation lists supply voltage 24 VDC -20/+25%, ripple (P-P) 10% or less, Class 2. for this model. Confirm the supply at the installation site matches, including any tolerance on the incoming feed, before the part is ordered.
How much does the GL-VM30LN weigh?
The documented weight is Transmitter 780 g; Receiver 790 g.. Use it for lifting, rail-loading and shipping decisions, and quote it when a handling study is required for the installation.
Related & compatible parts
Keyence
AP-32K
Genuine surplus Keyence AP-32K digital pressure sensor — verified NPN two-output unit with 1–5 V analog output, ready…
Keyence
AP-33KP
Genuine Keyence AP-33KP digital pressure sensor, surplus/refurbished, verified condition. Positive pressure, PNP, 0–145 PSI.
Keyence
EH-114
Genuine surplus Keyence EH-114 ES series M14 shielded sensor head, verified condition with practical lead times from Autronexa.
Keyence
AP-31K
Genuine surplus Keyence AP-31K negative-pressure sensor, verified and ready to ship — a practical alternative to OEM lead…
News & guides for Keyence
Keyence spare parts: buying guide, series overview and how to order
Keyence spare parts buying guide: 5 parts online, popular series, condition options and how our RFQ process works.
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…
