Keyence Vibration Monitoring GL-V series

Keyence GL-VM30LN

Vibration Monitoring

Manufacturer: Keyence Part Number: GL-VM30LN

Small & robust metal Type 4 safety light curtain, body protection type, 30 beam axes, NPN output, 1200 mm total length.

  • New Surplus
  • Available on request
Call us

Availability & pricing

Condition Price Stock / lead time Action
New Surplus On request Available on request

Ships within 7 business days

Technical specifications

Model GL-VM30LN
Brand Keyence
Series GL-V series
Safety light curtain Transmitter + Receiver set (Type 4 ESPE / AOPD)
Synchronization Optical synchronization
Light source Infrared LED (850 nm), Exempt Group (IEC62471)
Effective angular aperture up to ±2.5° (at 3 m or above)
Detection mode ON when all beam axes are received
Interference prevention up to 2 units by series connection and switch setting
Protection type Body protection
Minimum detectable object size ø45 mm
Number of beam axes 30
Beam axis spacing 40 mm
Detection height 1160 mm
Total length 1200 mm
Detecting distance 0.3 to 15 m
Response time (OSSD, channel 0, ON→OFF) max. 5.1 ms
Built-in ports None
Protocols None
Communication expansion None
Supply voltage 24 VDC -20/+25%, ripple (P-P) 10% or less, Class 2
Maximum load current 150 mA or less
Residual voltage (ON) up to 2.5 V (5 m cable); OFF voltage: up to 2.0 V (5 m cable)
Leakage current up to 0.8 mA; max. load capacity: 0.8 µF; load wiring resistance: up to 2.5 Ω
Inputs short-circuit current approx. 3 mA
Safety standards IEC61496-1/-2 (Type 4 ESPE/AOPD), EN ISO13849-1 (Category 4, PL e), IEC61508 (SIL3), UL60947-1 / CSA C22.2 No.60947-1, UL1998
EMC IEC/EN61496-1, EN55011 Class A, FCC Part15B Class A, ICES-003 Class A
Protection circuit Supply reverse-connection, per-output short-circuit and surge protection
Current consumption (indicator ON) Transmitter max. 128 mA; Receiver max. 142 mA (OSSD output current not included)
Control output (OSSD) Transistor output x2 (NPN)
Operating temperature -30 to +55 °C (No freezing)
Storage temperature -30 to +70 °C (No freezing)
Relative humidity up to 95 % RH (no condensation)
Ambient light Incandescent lamp 3,000 lux or less; Sunlight 20,000 lux or less
Protection rating IP65/IP67 (IEC60529)
Overvoltage category II
Vibration resistance 5 to 150 Hz, 1G, 10 cycles each in X/Y/Z
Shock resistance 15 G, 6 ms pulses, 100 times each in X/Y/Z
Material Main unit Aluminum alloy; upper/lower case PPS (GF40%); front cover Polycarbonate, SUS304
Dimensions (H×W×D) Not available
Weight Transmitter 780 g; Receiver 790 g

Description

The GL-VM30LN is a catalog part supplied for replacement and new-build use in industrial control installations. Every rating below is taken from the manufacturer documentation for this part number. Headline figures: supply voltage 24 VDC -20/+25%, ripple (P-P) 10% or less, Class 2; weight Transmitter 780 g; Receiver 790 g; operating temperature -30 to +55 °C (No freezing)

Electrical Ratings

Supply voltage is 24 VDC -20/+25%, ripple (P-P) 10% or less, Class 2. match this against the supply available at the installation site, including any tolerance on the incoming feed. Maximum load current is 150 mA or less. confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Residual voltage (ON) is up to 2.5 V (5 m cable); OFF voltage: up to 2.0 V (5 m cable). match this against the supply available at the installation site, including any tolerance on the incoming feed. Leakage current is up to 0.8 mA; max. load capacity: 0.8 µF; load wiring resistance: up to 2.5 Ω. confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Current consumption (indicator ON) is Transmitter max. 128 mA; Receiver max. 142 mA (OSSD output current not included). confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Control output (OSSD) is Transistor output x2 (NPN). compare this against the requirement it must satisfy in the application before release to site. Overvoltage category is II. match this against the supply available at the installation site, including any tolerance on the incoming feed. Vibration resistance is 5 to 150 Hz, 1G, 10 cycles each in X/Y/Z. confirm the installed location falls within this environmental capability. Shock resistance is 15 G, 6 ms pulses, 100 times each in X/Y/Z. confirm the installed location falls within this environmental capability.

Mechanical & Dimensional Data

Minimum detectable object size is ø45 mm. take this measurement into account when setting panel depth, rail position or enclosure clearance, since oversize is the normal reason a correct part will not physically fit. Detection height is 1160 mm. take this measurement into account when setting panel depth, rail position or enclosure clearance, since oversize is the normal reason a correct part will not physically fit. Total length is 1200 mm. take this measurement into account when setting panel depth, rail position or enclosure clearance, since oversize is the normal reason a correct part will not physically fit. Material is Main unit Aluminum alloy; upper/lower case PPS (GF40%); front cover Polycarbonate, SUS304. the material determines corrosion behaviour and thermal performance in the installed environment. Weight is Transmitter 780 g; Receiver 790 g. factor this into lifting, rail-loading and shipping decisions; it is also the figure to quote when a handling study is required.

Environmental & Compliance Ratings

Interference prevention is up to 2 units by series connection and switch setting. use this to confirm the part is acceptable in the classified area of the installation, and to support the documentation in the plant safety file. Safety standards is IEC61496-1/-2 (Type 4 ESPE/AOPD), EN ISO13849-1 (Category 4, PL e), IEC61508 (SIL3), UL60947-1 / CSA C22.2 No.60947-1, UL1998. compare this against the requirement it must satisfy in the application before release to site. Operating temperature is -30 to +55 °C (No freezing). check the enclosure temperature at the planned mounting location stays inside this band during the hottest operating period. Storage temperature is -30 to +70 °C (No freezing). observe this figure during transport and warehouse storage, which are not the same condition as operation. Relative humidity is up to 95 % RH (no condensation). maintain the stated humidity range in the cabinet; condensation is the usual cause of failure in equipment installed in humid plant rooms. Ambient light is Incandescent lamp 3,000 lux or less; Sunlight 20,000 lux or less. check the enclosure temperature at the planned mounting location stays inside this band during the hottest operating period.

Signal & Communication

Response time (OSSD, channel 0, ON→OFF) is max. 5.1 ms. this defines what the part reads or drives; confirm it matches the transducer or signal source wired to it.

Additional Verified Data

Safety light curtain is Transmitter + Receiver set (Type 4 ESPE / AOPD). Synchronization is Optical synchronization. Light source is Infrared LED (850 nm), Exempt Group (IEC62471). Effective angular aperture is up to ±2.5° (at 3 m or above). Detection mode is ON when all beam axes are received. Protection type is Body protection. Number of beam axes is 30. Beam axis spacing is 40 mm. Detecting distance is 0.3 to 15 m. Inputs is short-circuit current approx. 3 mA. EMC is IEC/EN61496-1, EN55011 Class A, FCC Part15B Class A, ICES-003 Class A. Protection rating is IP65/IP67 (IEC60529).

Models in This Series

Autronexa currently lists this product entry as the only model in its entry. Cross-reference requests for equivalent or superseded part numbers are handled on request.

Confirming the Correct Variant Before Ordering

Read the part number marked on the unit being replaced and compare it character by character with the ordering code above, including any option suffix. Check the values in the technical specification table of this page against the nameplate on the existing unit rather than against a previous purchase record. Confirm the supply voltage available at the installation site is 24 VDC -20/+25%, ripple (P-P) 10% or less, Class 2, which is the documented requirement for this model.

Request a Quote

Autronexa supplies the GL-VM30LN as a quote-based item. Send the part number, quantity and destination for current stock, lead time and pricing; no fixed price is published for this part.

Frequently asked questions

What is the GL-VM30LN?

Keyence GL-VM30LN is an industrial automation component we supply from surplus and refurbished stock. Confirm the exact configuration, condition and lead time with our team before purchase.

Is the GL-VM30LN in stock, and what is the lead time?

We list the GL-VM30LN as in stock in New Surplus condition. Request a quote for current availability, pricing and confirmed lead time — most items ship within 1–3 business days.

Do you provide a datasheet for the GL-VM30LN?

Where available, the product page links the original manufacturer datasheet (PDF). Use the request-a-quote form to receive the full documentation pack and compliance information.

Can the GL-VM30LN be cross-referenced to an equivalent?

Many automation parts have equivalents or legacy replacements. Send us the GL-VM30LN together with your application details and we will confirm compatibility and alternatives.

What input voltage does the GL-VM30LN use?

The GL-VM30LN operates at 24 VDC -20/+25%, ripple (P-P) 10% or less, Class 2. Verify the exact range and any hazardous-area limits against the product label before installation, because input requirements vary by ordered variant.

What is the operating temperature range of the GL-VM30LN?

The GL-VM30LN operating temperature is listed as -30 to +55 °C (No freezing). Stay within the documented band during operation; storage limits may differ. Elevated ambient conditions can reduce the continuous current or power rating of the module.

What are the dimensions and weight of the GL-VM30LN?

The GL-VM30LN measures Not available and weighs Transmitter 780 g; Receiver 790 g. Confirm clearance and rack or panel space before ordering.

What is the GL-VM30LN and what is it used for?

The GL-VM30LN is a industrial component device. It is used in industrial control and automation systems where a verified part number and specification match are required for replacement or new design.

What supply voltage does the GL-VM30LN need?

The manufacturer documentation lists supply voltage 24 VDC -20/+25%, ripple (P-P) 10% or less, Class 2. for this model. Confirm the supply at the installation site matches, including any tolerance on the incoming feed, before the part is ordered.

How much does the GL-VM30LN weigh?

The documented weight is Transmitter 780 g; Receiver 790 g.. Use it for lifting, rail-loading and shipping decisions, and quote it when a handling study is required for the installation.

Related & compatible parts

Keyence

AP-32K

Genuine surplus Keyence AP-32K digital pressure sensor — verified NPN two-output unit with 1–5 V analog output, ready…

In Stock

Keyence

AP-33KP

Genuine Keyence AP-33KP digital pressure sensor, surplus/refurbished, verified condition. Positive pressure, PNP, 0–145 PSI.

In Stock

Keyence

EH-114

Genuine surplus Keyence EH-114 ES series M14 shielded sensor head, verified condition with practical lead times from Autronexa.

In Stock

Keyence

AP-31K

Genuine surplus Keyence AP-31K negative-pressure sensor, verified and ready to ship — a practical alternative to OEM lead…

In Stock

News & guides for Keyence

View all articles

Request a quote for this part

Part number: GL-VM30LN

We reply within one business day.

GL-VM30LN Quote reply within 1 business day