Technical specifications
| Number of channels | One, fully floating |
|---|---|
| Input and output signal range | 0 to 20mA |
| Maximum load resistance | 800Ω (16V at 20mA) |
| Input resistance | ≤200Ω (4V at 20mA) |
| Transfer accuracy at 20°C | Better than 20µA |
| Temperature drift | <1µA/°C |
| Input and output circuit ripple | <40µA peak-to-peak |
| Response time | Settles to within 10% of final value after typically 55ms |
| Power requirement | 65mA typical at 24V; 90mA maximum at 20 to 35V |
| Weight | 150g |
Description
The MTL3045 is a single-channel, fully floating isolator that passes a 0/20mA or 4/20mA signal from a controller to drive a current-to-pressure converter, position actuator, or other load up to 800Ω in a hazardous area. Maintenance and procurement teams choose genuine surplus or refurbished units when an OEM replacement path is slow or costly. Autronexa verifies each unit against OEM datasheet markings before it ships.
What the MTL3045 Does in a Control Loop
This module sits between the safe-area controller and the field device. It carries the control signal into Zone 0, IIC, T4–6 or Div 1, Group A hazardous locations when suitably certified. Because the input and output circuits are fully floating, the loop keeps its integrity across the barrier. The low input resistance of ≤200Ω (4V at 20mA) limits the burden on the controller output. Meanwhile, the high output capability of 16V at 20mA supports loads up to 800Ω. For a buyer, that means one isolator can drive an I/P converter without an extra booster in many loop designs. This unit can also work with the MTL3046B to transfer measurement or control signals between two safe areas through a hazardous zone.

Signal Quality and Environmental Performance
Accuracy matters when the field device sets a valve position. This unit holds transfer accuracy better than 20µA at 20°C. Temperature drift stays below 1µA/°C, so loop error remains predictable across plant temperature swings. Input and output circuit ripple is under 40µA peak-to-peak, which keeps noise away from the I/P converter. Response time settles to within 10% of final value after typically 55ms, fast enough for most process control loops. Power draw is 65mA typical at 24V, with 90mA maximum at 20 to 35V. Internal dissipation is 1.5W typical at 24V with a 20mA signal. A replaceable 125mA glass fuse protects the unit. The module weighs 150g.

Why Genuine Surplus Fits This Isolator
Signal isolators are often replaced on a maintenance schedule rather than at failure. That creates a steady supply of genuine surplus and refurbished unit units from decommissioned panels. Autronexa tests each unit against OEM datasheet specifications and functionally verifies it before listing. You get a verified part with clear lead times instead of waiting on an OEM backlog. Because This unit is a long-established MTL design, matching the exact model and certification marking is the main sourcing check. Confirm the safety description on your unit: 28V, 300Ω, 93mA, Um = 250V rms or dc. Ask Autronexa for the condition grade and current availability before you commit.
Buyer Checklist Before You Order
Start with the loop load. If your I/P converter or actuator needs more than 800Ω drive, this model is not the right fit. Next, confirm the hazardous-area certification matches your installation. Then verify the signal range your controller sends: 0 to 20mA covers both 4/20mA and 0/20mA use. Finally, check the fuse rating and power supply voltage against your panel. For replacement planning, keep one verified spare on the shelf. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine MTL MTL3045, or a clone?
Autronexa verifies each MTL3045 against OEM datasheet markings and part-number cross-reference before listing. Units are genuine surplus or professionally refurbished, not grey-market copies.
What condition will the MTL3045 arrive in?
Units ship in the condition grade stated on the listing, typically refurbished and functionally verified against OEM datasheet specifications. Ask Autronexa for the specific grade before ordering.
How fast can you ship the MTL3045?
Contact Autronexa for current lead time. Surplus and refurbished stock is ready to ship once condition and availability are confirmed for your order.
Can the MTL3045 drive a load above 800Ω?
No. The MTL3045 supports a maximum load resistance of 800Ω, which corresponds to 16V at 20mA. Check your I/P converter or actuator load before selecting this model.
Does the MTL3045 work with the MTL3046B?
Yes. The MTL3045 can be used with the MTL3046B to transfer measurement or control signals through a hazardous area separating two safe areas.
Related & compatible parts
MTL
MTL5074
MTL MTL5074 Drives & Inverters. mV/THC: ±15µV or ±0.05% of input value; RTD: ±80mΩ. Supplied for MRO and…
MTL
SD32X
Genuine MTL SD32X surge protection device with 32Vdc nominal voltage and 400 mA nominal current. Verified surplus stock…
MTL
SD32T3
Genuine MTL SD32T3 surge protection device with 3-terminal configuration and 10-year warranty. Verified surplus and refurbished units from…
MTL
SD32R
Genuine surplus MTL SD32R surge protector with 32 Vdc nominal voltage, 400 mA nominal current, and high bandwidth…
News & guides for MTL
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…