MTL PLCs & Controllers

MTL MTL3045

Controller to drive a current-to-pressure

Manufacturer: MTL Part Number: MTL3045

Genuine surplus MTL3045 isolator passes 0-20mA to hazardous-area I/P converters and actuators with 800Ω load capability and verified condition.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Number of channels One, fully floating
Input and output signal range 0 to 20mA
Maximum load resistance 800Ω (16V at 20mA)
Input resistance ≤200Ω (4V at 20mA)
Transfer accuracy at 20°C Better than 20µA
Temperature drift <1µA/°C
Input and output circuit ripple <40µA peak-to-peak
Response time Settles to within 10% of final value after typically 55ms
Power requirement 65mA typical at 24V; 90mA maximum at 20 to 35V
Weight 150g

Description

The MTL3045 is a single-channel, fully floating isolator that passes a 0/20mA or 4/20mA signal from a controller to drive a current-to-pressure converter, position actuator, or other load up to 800Ω in a hazardous area. Maintenance and procurement teams choose genuine surplus or refurbished units when an OEM replacement path is slow or costly. Autronexa verifies each unit against OEM datasheet markings before it ships.

What the MTL3045 Does in a Control Loop

This module sits between the safe-area controller and the field device. It carries the control signal into Zone 0, IIC, T4–6 or Div 1, Group A hazardous locations when suitably certified. Because the input and output circuits are fully floating, the loop keeps its integrity across the barrier. The low input resistance of ≤200Ω (4V at 20mA) limits the burden on the controller output. Meanwhile, the high output capability of 16V at 20mA supports loads up to 800Ω. For a buyer, that means one isolator can drive an I/P converter without an extra booster in many loop designs. This unit can also work with the MTL3046B to transfer measurement or control signals between two safe areas through a hazardous zone.

Figure 1: Front view of the MTL MTL3045 Controller to drive a current-to-pressure showing its physical design and enclosure.

Signal Quality and Environmental Performance

Accuracy matters when the field device sets a valve position. This unit holds transfer accuracy better than 20µA at 20°C. Temperature drift stays below 1µA/°C, so loop error remains predictable across plant temperature swings. Input and output circuit ripple is under 40µA peak-to-peak, which keeps noise away from the I/P converter. Response time settles to within 10% of final value after typically 55ms, fast enough for most process control loops. Power draw is 65mA typical at 24V, with 90mA maximum at 20 to 35V. Internal dissipation is 1.5W typical at 24V with a 20mA signal. A replaceable 125mA glass fuse protects the unit. The module weighs 150g.

Figure 2: Technical layout and connection details for the MTL MTL3045 Controller to drive a current-to-pressure.

Why Genuine Surplus Fits This Isolator

Signal isolators are often replaced on a maintenance schedule rather than at failure. That creates a steady supply of genuine surplus and refurbished unit units from decommissioned panels. Autronexa tests each unit against OEM datasheet specifications and functionally verifies it before listing. You get a verified part with clear lead times instead of waiting on an OEM backlog. Because This unit is a long-established MTL design, matching the exact model and certification marking is the main sourcing check. Confirm the safety description on your unit: 28V, 300Ω, 93mA, Um = 250V rms or dc. Ask Autronexa for the condition grade and current availability before you commit.

Buyer Checklist Before You Order

Start with the loop load. If your I/P converter or actuator needs more than 800Ω drive, this model is not the right fit. Next, confirm the hazardous-area certification matches your installation. Then verify the signal range your controller sends: 0 to 20mA covers both 4/20mA and 0/20mA use. Finally, check the fuse rating and power supply voltage against your panel. For replacement planning, keep one verified spare on the shelf. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: MTL3045-datasheet.pdf

Frequently asked questions

Is this a genuine MTL MTL3045, or a clone?

Autronexa verifies each MTL3045 against OEM datasheet markings and part-number cross-reference before listing. Units are genuine surplus or professionally refurbished, not grey-market copies.

What condition will the MTL3045 arrive in?

Units ship in the condition grade stated on the listing, typically refurbished and functionally verified against OEM datasheet specifications. Ask Autronexa for the specific grade before ordering.

How fast can you ship the MTL3045?

Contact Autronexa for current lead time. Surplus and refurbished stock is ready to ship once condition and availability are confirmed for your order.

Can the MTL3045 drive a load above 800Ω?

No. The MTL3045 supports a maximum load resistance of 800Ω, which corresponds to 16V at 20mA. Check your I/P converter or actuator load before selecting this model.

Does the MTL3045 work with the MTL3046B?

Yes. The MTL3045 can be used with the MTL3046B to transfer measurement or control signals through a hazardous area separating two safe areas.

Related & compatible parts

MTL

MTL5074

MTL MTL5074 Drives & Inverters. mV/THC: ±15µV or ±0.05% of input value; RTD: ±80mΩ. Supplied for MRO and…

Available on request

MTL

SD32X

Genuine MTL SD32X surge protection device with 32Vdc nominal voltage and 400 mA nominal current. Verified surplus stock…

In Stock

MTL

SD32T3

Genuine MTL SD32T3 surge protection device with 3-terminal configuration and 10-year warranty. Verified surplus and refurbished units from…

In Stock

MTL

SD32R

Genuine surplus MTL SD32R surge protector with 32 Vdc nominal voltage, 400 mA nominal current, and high bandwidth…

In Stock

News & guides for MTL

View all articles

Request a quote for this part

Part number: MTL3045

We reply within one business day.

MTL3045 Quote reply within 1 business day