MTL PLCs & Controllers

MTL MTL3042

Controller to drive a current-to-pressure

Manufacturer: MTL Part Number: MTL3042

Genuine surplus MTL3042 controller isolator for 4-20mA I/P converters. Verified condition, clear lead times, and practical sourcing help from Autronexa.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Number of channels One, fully floating
Input voltage 11 to 35V dc
Input and output signal range 4 to 20mA
Input and output circuit ripple <100µA peak-to-peak
Transfer accuracy at 20°C Better than 50µA
Temperature drift <2µA/°C
Response time Settles to within 10% of final value after typically 70ms
Power dissipation 0.4W typical at 24V with 20mA signal; 0.5W maximum at 35V with 20mA signal
Replaceable fuse 50mA, 5x20mm glass to DIN 41571 sht.2, semi-time-lag (M)
Weight 160g

Description

When a 4-20mA signal must reach an I/P converter inside a hazardous area, the MTL3042 controller isolator keeps that loop accurate and safe. Autronexa supplies genuine surplus and refurbished units with verified condition, giving maintenance teams a practical alternative to long OEM lead times.

What the MTL3042 Does in a Current Loop

This unit acts like a direct-current transformer. It is always powered from the safe-area side, so the same current flows in the safe and hazardous-area circuits. This lets you control the loop from either side. The unit is intended primarily for isolating and passing on a 4-20mA signal from a controller to drive a current-to-pressure converter or a position actuator. One fully floating channel handles the isolation. Because the module introduces a volt drop, loops sensitive to that drop should use the separately powered MTL3045 instead.

Figure 1: Front view of the MTL MTL3042 Controller to drive a current-to-pressure showing its physical design and enclosure.

Key Performance Details Buyers Should Check

Ripple on the input and output circuit stays below 100µA peak-to-peak, which suits sensitive I/P drives. Transfer accuracy at 20°C is better than 50µA. Temperature drift stays below 2µA/°C, so accuracy holds across normal plant temperature swings. The response settles to within 10% of final value after typically 70ms. Power dissipation is 0.4W typical at 24V with a 20mA signal, and 0.5W maximum at 35V with 20mA. A replaceable 50mA fuse protects the unit.

Figure 2: Technical layout and connection details for the MTL MTL3042 Controller to drive a current-to-pressure.

Why Genuine Surplus Fits This Isolator

Control-room upgrades and panel replacements often leave working unit units unused. Autronexa tests each refurbished module against OEM datasheet specifications and verifies markings before it ships. That means you get a genuine part with a known condition, not an unverified pull. For maintenance managers, this shortens the path from failure to repair when an OEM order would stall the loop. Surplus and refurbished units are ready to ship once verified.

Matching This unit to Your Loop

Before ordering, confirm the hazardous-area certification suits your installation. The I/P converter may sit in Zone 0, IIC, T4-6 if suitably certified, or Div 1, Group A. Check that your controller output matches the 4-20mA range and that the 11 to 35V dc input supply is available. If your loop is sensitive to volt drop, compare against the MTL3045. For lower-accuracy closed-loop work, the MTL3043 may be acceptable. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: MTL3042-datasheet.pdf

Frequently asked questions

Is this a genuine MTL3042, or a clone?

Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it is listed. We supply genuine surplus and refurbished modules, not copies.

What condition will the MTL3042 arrive in?

Units are supplied refurbished by default and are tested against OEM datasheet specifications. Contact Autronexa for the current condition grade on stock.

How fast can you ship the MTL3042?

Lead time depends on verified stock at the time of order. Contact Autronexa for current lead time and availability.

Does the MTL3042 suit a Zone 0 I/P converter?

The source data states the I/P converter may be located in Zone 0, IIC, T4-6 hazardous areas if suitably certified, or Div 1, Group A. Confirm your certification requirements with Autronexa before ordering.

Related & compatible parts

MTL

MTL4521L

Genuine surplus MTL4521L loop-powered solenoid/alarm driver for Zone 0 IIC hazardous areas, verified and ready to ship from…

In Stock

MTL

MTL3013

Genuine surplus MTL3013 two-channel switch/proximity detector relay for hazardous-area sensors, verified and ready to ship from Autronexa.

In Stock

MTL

MTL3073

Genuine surplus MTL3073 temperature converter for hazardous-area sensors, verified and ready to ship from Autronexa.

In Stock

MTL

MTL3045

Genuine surplus MTL3045 isolator passes 0-20mA to hazardous-area I/P converters and actuators with 800Ω load capability and verified…

In Stock

News & guides for MTL

View all articles

Request a quote for this part

Part number: MTL3042

We reply within one business day.

MTL3042 Quote reply within 1 business day