MTL MTL3042
Controller to drive a current-to-pressure
Genuine surplus MTL3042 controller isolator for 4-20mA I/P converters. Verified condition, clear lead times, and practical sourcing help from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Number of channels | One, fully floating |
|---|---|
| Input voltage | 11 to 35V dc |
| Input and output signal range | 4 to 20mA |
| Input and output circuit ripple | <100µA peak-to-peak |
| Transfer accuracy at 20°C | Better than 50µA |
| Temperature drift | <2µA/°C |
| Response time | Settles to within 10% of final value after typically 70ms |
| Power dissipation | 0.4W typical at 24V with 20mA signal; 0.5W maximum at 35V with 20mA signal |
| Replaceable fuse | 50mA, 5x20mm glass to DIN 41571 sht.2, semi-time-lag (M) |
| Weight | 160g |
Description
When a 4-20mA signal must reach an I/P converter inside a hazardous area, the MTL3042 controller isolator keeps that loop accurate and safe. Autronexa supplies genuine surplus and refurbished units with verified condition, giving maintenance teams a practical alternative to long OEM lead times.
What the MTL3042 Does in a Current Loop
This unit acts like a direct-current transformer. It is always powered from the safe-area side, so the same current flows in the safe and hazardous-area circuits. This lets you control the loop from either side. The unit is intended primarily for isolating and passing on a 4-20mA signal from a controller to drive a current-to-pressure converter or a position actuator. One fully floating channel handles the isolation. Because the module introduces a volt drop, loops sensitive to that drop should use the separately powered MTL3045 instead.

Key Performance Details Buyers Should Check
Ripple on the input and output circuit stays below 100µA peak-to-peak, which suits sensitive I/P drives. Transfer accuracy at 20°C is better than 50µA. Temperature drift stays below 2µA/°C, so accuracy holds across normal plant temperature swings. The response settles to within 10% of final value after typically 70ms. Power dissipation is 0.4W typical at 24V with a 20mA signal, and 0.5W maximum at 35V with 20mA. A replaceable 50mA fuse protects the unit.

Why Genuine Surplus Fits This Isolator
Control-room upgrades and panel replacements often leave working unit units unused. Autronexa tests each refurbished module against OEM datasheet specifications and verifies markings before it ships. That means you get a genuine part with a known condition, not an unverified pull. For maintenance managers, this shortens the path from failure to repair when an OEM order would stall the loop. Surplus and refurbished units are ready to ship once verified.
Matching This unit to Your Loop
Before ordering, confirm the hazardous-area certification suits your installation. The I/P converter may sit in Zone 0, IIC, T4-6 if suitably certified, or Div 1, Group A. Check that your controller output matches the 4-20mA range and that the 11 to 35V dc input supply is available. If your loop is sensitive to volt drop, compare against the MTL3045. For lower-accuracy closed-loop work, the MTL3043 may be acceptable. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine MTL3042, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it is listed. We supply genuine surplus and refurbished modules, not copies.
What condition will the MTL3042 arrive in?
Units are supplied refurbished by default and are tested against OEM datasheet specifications. Contact Autronexa for the current condition grade on stock.
How fast can you ship the MTL3042?
Lead time depends on verified stock at the time of order. Contact Autronexa for current lead time and availability.
Does the MTL3042 suit a Zone 0 I/P converter?
The source data states the I/P converter may be located in Zone 0, IIC, T4-6 hazardous areas if suitably certified, or Div 1, Group A. Confirm your certification requirements with Autronexa before ordering.
Related & compatible parts
MTL
MTL4521L
Genuine surplus MTL4521L loop-powered solenoid/alarm driver for Zone 0 IIC hazardous areas, verified and ready to ship from…
MTL
MTL3013
Genuine surplus MTL3013 two-channel switch/proximity detector relay for hazardous-area sensors, verified and ready to ship from Autronexa.
MTL
MTL3073
Genuine surplus MTL3073 temperature converter for hazardous-area sensors, verified and ready to ship from Autronexa.
MTL
MTL3045
Genuine surplus MTL3045 isolator passes 0-20mA to hazardous-area I/P converters and actuators with 800Ω load capability and verified…
News & guides for MTL
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…
