MTL Proximity Probes & Sensors

MTL MTL3013

Switch/Proximity Detector

Manufacturer: MTL Part Number: MTL3013

Genuine surplus MTL3013 two-channel switch/proximity detector relay for hazardous-area sensors, verified and ready to ship from Autronexa.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Number of channels Two, interconnected, fully floating
Contact rating 250V 5A 100VA (ac); 250V 5A 100W (dc)
Response time 10ms typical
Hysteresis 200µA (650Ω) typical
Contact life expectancy 1.5 x 105 operations at max. load; >106 operations at 200V ac peak or dc, 10VA (resistive load)
Voltage applied to sensor 7.0 to 8.5V dc from 970Ω
Power requirement 55mA typical at 24V; 75mA maximum at 20 to 35V
Weight 170g

Description

The MTL3013 from MTL is a two-channel switch/proximity detector relay that lets two safe-area loads be controlled independently by switches or proximity detectors mounted in hazardous areas. For maintenance and procurement teams, a verified surplus or refurbished unit keeps intrinsic-safety circuits running without waiting on OEM lead times.

What the MTL3013 Does in a Safety Loop

This unit carries the same basic function as the MTL3011 but packs two channels into one unit. Each channel drives a single-pole relay that opens when de-energised, with a typical response time of 10ms. The two input circuits are interconnected yet fully floating, so a single changeover switch can control both safe-area loads when the application allows. A phase reversal switch on top of the unit lets each channel signal an alarm condition for either sensor state, and an LED shows relay status per channel. Because the unit provides relay contacts rather than line-fault detection, applications needing fault monitoring should specify the MTL3011 or MTL3014 instead.

Figure 1: Front view of the MTL MTL3013 Switch/Proximity Detector showing its physical design and enclosure.

Key Ratings Buyers Should Confirm

The relay contact rating is 250V 5A 100VA (ac) and 250V 5A 100W (dc), which suits many interposing and alarm duties. Contact life expectancy reaches 1.5 x 105 operations at maximum load, and more than 106 operations at 200V ac peak or dc, 10VA into a resistive load. Input switching is defined by NAMUR and DIN19234 thresholds: output closed above 2.1mA and open below 1.2mA, with 200µA (650Ω) typical hysteresis. Reactive loads must be adequately suppressed. The unit weighs 170g and carries a replaceable 80mA fuse.

Figure 2: Technical layout and connection details for the MTL MTL3013 Switch/Proximity Detector.

Surplus and Refurbished, Verified

Genuine unit units are increasingly sourced from surplus channels rather than new production runs. Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference, then functionally checks the relay channels before dispatch. That approach gives buyers a practical alternative to long OEM lead times while keeping the intrinsic-safety rating intact. Compare This unit with related options before ordering:

  • MTL3011: single channel with line-fault detection.
  • MTL3014: line-fault detection variant.
  • unit: two interconnected, fully floating channels without line-fault detection.

Confirm your exact model, revision and condition grade with the sourcing team. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: MTL3013-datasheet.pdf

Frequently asked questions

Is this a genuine MTL MTL3013, or a clone?

Autronexa verifies each MTL3013 against OEM datasheet markings and part-number cross-reference before it enters stock, so you receive a genuine unit rather than a copy.

What condition will the MTL3013 arrive in?

Units are supplied as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask about current surplus condition grades when you enquire.

How fast can you ship the MTL3013?

Contact Autronexa for current lead time. Stocked surplus and refurbished units are typically ready to ship once condition and availability are confirmed for your order.

Does the MTL3013 suit my hazardous-area sensor circuit?

The MTL3013 accepts switches or proximity detectors in Zone 0, IIC, T6 and Div 1, Group A locations, with NAMUR switching thresholds of 2.1mA closed and 1.2mA open. Confirm your sensor certification with our team.

Related & compatible parts

MTL

MTL4646Y

Genuine surplus MTL4646Y controller drives current/pressure converters with HART support and 800Ω load capacity. Verified condition, ready to…

In Stock

MTL

MTL3081

Genuine surplus MTL3081 thermocouple isolator with ±50mV input, non-energy-storing terminals, and optional burnout safety drive. Verified and ready…

In Stock

MTL

MTL3046B

Genuine surplus MTL3046B smart transmitter repeater with 15V at 20mA transmitter supply and 4 to 20mA signal with…

In Stock

MTL

SLP16D

Genuine surplus MTL SLP16D modules provide hybrid surge protection for two process loops, with 20kA surge current and…

In Stock

News & guides for MTL

View all articles

Request a quote for this part

Part number: MTL3013

We reply within one business day.

MTL3013 Quote reply within 1 business day