MTL Circuit Protection

MTL SLP16D

Module provides full hybrid surge protection

Manufacturer: MTL Part Number: SLP16D

Genuine surplus MTL SLP16D modules provide hybrid surge protection for two process loops, with 20kA surge current and 16V nominal voltage.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Nominal voltage 16V
Rated voltage (MCOV) 18V
Nominal current 1.50A
Maximum surge current 20kA (8/20µs waveform) per line
Nominal discharge current 3kA (8/20µs)
Response time <1ns
Capacitance Line to Line: 60pF
Degree of protection IP20
Ambient temperature -40 to +80°C

Description

How do you protect two process loops from damaging surges without adding complexity? The MTL SLP16D is a full hybrid surge protection module that safeguards two loops per unit, featuring a 20kA maximum surge current and a 16V nominal voltage. For maintenance and procurement teams, genuine surplus or refurbished units offer a practical path to reliable protection when OEM lead times stretch.

What Does this module Module Do in a Process Loop?

The MTL this module sits between field wiring and your control system, diverting surge currents safely to earth while clamping output voltages. Its multi-stage hybrid circuit combines solid-state electronics with a gas-filled discharge tube, delivering a 20kA maximum surge current per line. The module adds only a tiny voltage drop and allows signals to pass with very little attenuation, so loop performance stays intact. With a response time of less than 1ns, it reacts instantaneously to surges and resets automatically. This module is part of the MTL SLP range, designed for high packing densities and simple installation on T-section DIN rail.

Figure 1: Front view of the MTL SLP16D Module provides full hybrid surge protection showing its physical design and enclosure.

Why Choose Genuine Surplus for this module?

When an this module fails, waiting weeks for a new unit can leave loops exposed. Autronexa supplies genuine surplus and professionally refurbished MTL modules that are tested against OEM datasheet specifications and functionally verified by our sourcing team. This approach gives you a verified alternative to long OEM lead times, with clear condition grading and practical lead times. Because this module is a current model in the SLP range, surplus availability varies—contact us for current stock and condition details. Every unit is checked for authenticity, so you avoid grey-market clones that may not meet the original 20kA surge rating.

Figure 2: Technical layout and connection details for the MTL SLP16D Module provides full hybrid surge protection.

Key Specifications Buyers Should Verify

When sourcing this module, confirm the voltage rating matches your loop: the nominal voltage is 16V and the rated voltage (MCOV) is 18V. The module handles a nominal current of 1.50A and a nominal discharge current of 3kA (8/20μs). Also check the capacitance of 60pF line-to-line, which suits high-bandwidth applications. This module carries a degree of protection of IP20 and operates from -40 to +80°C. For safety-critical loops, verify that the ATEX-certified intrinsically safe version is required—the SLP range includes ATEX-certified models, but confirm the exact variant with your supplier. Autronexa provides technical sourcing help across MTL and other leading automation brands.

Sourcing this module with Confidence

Request the exact model and any revision details when you inquire. Ask for the condition—surplus or refurbished—and confirm that the unit includes the plug/header screw terminal strip. This module mounts on T-section DIN rail (35 x 15mm), and one simple manual operation clamps it securely while providing a high-integrity earth connection. For adverse environments, a specially-plated DIN rail version is available separately. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is the MTL SLP16D a genuine module or a clone?

Autronexa verifies every MTL SLP16D against OEM datasheet markings and part-number cross-references. We supply genuine surplus and refurbished units, not grey-market copies.

What condition will the SLP16D arrive in?

Our default condition for the MTL SLP16D is refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available depending on stock.

How fast can you ship the SLP16D?

Lead time for the MTL SLP16D depends on current stock and condition. Contact Autronexa for a verified lead time and availability before ordering.

Does the SLP16D work with my existing process loops?

The MTL SLP16D provides full hybrid surge protection for two process loops and handles a nominal current of 1.50A. Confirm your loop voltage and current against the 16V nominal rating and 1.50A maximum load.

Related & compatible parts

MTL

SD16R

Genuine MTL SD16R surge protection device with 50MHz bandwidth and <1ns response time. Verified surplus and refurbished units…

In Stock

MTL

MTL4521L

Genuine surplus MTL4521L loop-powered solenoid/alarm driver for Zone 0 IIC hazardous areas, verified and ready to ship from…

In Stock

MTL

MTL3042

Genuine surplus MTL3042 controller isolator for 4-20mA I/P converters. Verified condition, clear lead times, and practical sourcing help…

In Stock

MTL

SD32

Genuine MTL SD32 surge protector with 32 VDC / 22 VAC rating, 250 mA nominal current, and fuse…

In Stock

News & guides for MTL

View all articles

Request a quote for this part

Part number: SLP16D

We reply within one business day.

SLP16D Quote reply within 1 business day