MTL Servo Drives & Motors

MTL MTL4521L

SOLENOID or ALARM DRIVER loop-powered

Manufacturer: MTL Part Number: MTL4521L

Genuine surplus MTL4521L loop-powered solenoid/alarm driver for Zone 0 IIC hazardous areas, verified and ready to ship from Autronexa.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Number of channels One
Input voltage 20 to 35V dc
Hazardous-area output Minimum output voltage 11.1V at 48mA; maximum output voltage 24V from 232Ω
Current limit 48mA minimum
Output ripple < 0.5% of maximum output, peak to peak
Response time Output within 10% of final value within 100ms
Safety description Uo=25V, Io=108mA, Po=0.68W, Um=253V rms or dc
SIL capability SIL3 single device (HFT=0) for de-energise function; SIL1 for energise function
Maximum current consumption 90mA at 24V
Power dissipation within unit 1.4W at 24V

Description

The MTL4521L from MTL is a loop-powered solenoid or alarm driver that lets a safe-area control signal operate a certified intrinsically safe load in a hazardous area. It suits maintenance and procurement teams needing a genuine, verified replacement without OEM lead-time delays. Autronexa supplies this module as genuine surplus or professionally refurbished stock, tested against OEM datasheet specifications and functionally verified by our sourcing team.

What this drive Does in a Control Loop

This single-channel module sits between the safe area and the hazardous area. It drives a certified intrinsically safe low-power load, as well as non-energy-storing simple apparatus such as an LED. The load may be located in a Zone 0, IIC, T4–6 hazardous area if suitably certified, or in a Div. 1, Group A hazardous location. A yellow LED indicator shows output status and is on when the output is active. Because the module is loop-powered, it takes its input from the 20 to 35V dc loop supply. Maximum current consumption is 90mA at 24V, and power dissipation within the unit is 1.4W at 24V.

Figure 1: Front view of the MTL MTL4521L SOLENOID or ALARM DRIVER loop-powered showing its physical design and enclosure.

Key Specifications at a Glance

Parameter this drive value
Channels One
Input voltage 20 to 35V dc
Hazardous-area output Minimum 11.1V at 48mA; maximum 24V from 232Ω
Current limit 48mA minimum
Output ripple < 0.5% of maximum output, peak to peak
Response time Output within 10% of final value within 100ms
Safety description Uo=25V, Io=108mA, Po=0.68W, Um=253V rms or dc
SIL capability SIL3 single device (HFT=0) for de-energise function; SIL1 for energise function

Compared with a standard MTLx521 driver, this drive offers a lower hazardous-area output current (108mA versus 147mA) and a minimum output voltage of 11.1V at 48mA. The MTLx521 specifies a minimum of 13.6V at 48mA and a maximum output of 24V from 180Ω. Both share the same 48mA minimum current limit and 20 to 35V dc input range.

Figure 2: Technical layout and connection details for the MTL MTL4521L SOLENOID or ALARM DRIVER loop-powered.

Why Genuine Surplus Makes Sense for This Module

this drive has been assessed for use in IEC 61508 functional safety applications, so authenticity matters. A clone or unverified unit can put the safety function at risk. Autronexa verifies each module against OEM datasheet markings and part-number cross-reference before it enters stock. Surplus and refurbished units are ready to ship, which helps when an OEM lead time would leave a loop out of service. For a single-channel driver like this, the practical alternative to waiting is a verified surplus unit with clear condition notes. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is the MTL4521L a genuine MTL module or a clone?

Autronexa verifies every MTL4521L against OEM datasheet markings and part-number cross-reference before listing it. We supply genuine surplus and refurbished units, not grey-market copies.

What condition will the MTL4521L arrive in?

The MTL4521L is supplied as genuine surplus or professionally refurbished stock, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the specific condition grade of the unit in stock.

How fast can Autronexa ship the MTL4521L?

Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability, and we will confirm the shipping date.

Does the MTL4521L support SIL3 applications?

The MTL4521L has been assessed for IEC 61508 functional safety. It is SIL3 capable for a single device (HFT=0) when the required function is to de-energise the output, and SIL1 capable when the function is to energise the output.

Related & compatible parts

MTL

MTL4041P

Genuine surplus MTL4041P isolator: high-power 4-20mA loop driver for hazardous-area transmitters, verified and ready to ship from Autronexa.

In Stock

MTL

MTL3021

Genuine surplus MTL3021 switch/voltage change module for hazardous-area control, verified condition and practical sourcing support from Autronexa.

In Stock

MTL

MTL4013

Genuine surplus MTL4013 two-channel unit for safe-area control from hazardous-area switches, with verified condition and fast sourcing from…

In Stock

MTL

MTL3081

Genuine surplus MTL3081 thermocouple isolator with ±50mV input, non-energy-storing terminals, and optional burnout safety drive. Verified and ready…

In Stock

News & guides for MTL

View all articles

Request a quote for this part

Part number: MTL4521L

We reply within one business day.

MTL4521L Quote reply within 1 business day