MTL I/O & Function Modules

MTL MTL4013

Controlled

Manufacturer: MTL Part Number: MTL4013

Genuine surplus MTL4013 two-channel unit for safe-area control from hazardous-area switches, with verified condition and fast sourcing from Autronexa.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Number of channels Two
Operating frequency dc to 5kHz
Maximum off-state voltage 35V
Maximum off-state leakage current 10µA
Maximum on-state current 50mA
Maximum on-state voltage drop [1+ (0.1 x current in mA)] V
Hysteresis 200µA (650Ω) nominal
Isolation 250V ac between safe and hazardous area circuits
Power requirement, Vs 47.5mA at 24V dc
Power dissipation within unit 1.15W at 24V

Description

The MTL4013 is a two-channel unit that lets safe-area loads be controlled by switches or proximity detectors in hazardous areas. Autronexa supplies genuine surplus and refurbished units, verified for condition and ready to support your maintenance schedule.

What the MTL4013 Does in Your Control Loop

When a hazardous-area switch or proximity detector must drive a safe-area load, the interface has to pass a clean, logic-compatible signal without compromising isolation. This unit handles that task with two independent channels. Each channel accepts a sensor circuit and provides a solid-state output, so a detector in a Zone 0 or Div.1 location can control equipment in the safe area. Because the output is solid-state, there are no moving contacts to wear. The unit also suits positive displacement flowmeters and some turbine meters, where a reliable pulse output is needed. Two LEDs on top show power and switch status, which simplifies troubleshooting during routine checks.

Figure 1: Front view of the MTL MTL4013 Controlled showing its physical design and enclosure.

Why Genuine Surplus Makes Sense for This Model

OEM lead times for interface modules can stretch when a line is down and a replacement is urgent. A genuine surplus or refurbished unit gives you a practical alternative. Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before it ships. You get the same terminal layout and the same hazardous-area safety description, without waiting on a factory backlog. For maintenance managers, that means a verified spare can be on the shelf before the next shutdown. Autronexa focuses on genuine parts, verified, so you can compare condition and lead time directly.

Figure 2: Technical layout and connection details for the MTL MTL4013 Controlled.

Specs That Matter on the Plant Floor

This unit operates from dc to 5kHz, which covers the pulse rates of many flowmeter and detector applications. Each output is Zener-diode protected against inductive loads, a practical detail when driving relays or solenoids. The maximum on-state current is 50mA, and the maximum off-state voltage is 35V. Power consumption is modest: 47.5mA at 24V dc, with 1.15W dissipated at 24V. Isolation between safe and hazardous area circuits is rated at 250V ac. These figures help you confirm the module fits your loop without guesswork. If you need earth fault detection, This unit can be used with an MTL4220 earth leakage detector via the optional link terminals. Note that separate detectors are needed to maintain isolation between the two channels.

Sourcing the Right Condition for Your Spares Strategy

Before ordering, confirm the exact model and terminal function match your panel drawing. Check whether your application needs the optional earth fault link, and decide between surplus and refurbished condition based on your spares policy. Autronexa provides hands-on sourcing help across Allen-Bradley, Bently Nevada, Siemens, Schneider and more. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: MTL4013-datasheet.pdf

Frequently asked questions

Is this a genuine MTL MTL4013, or a clone?

Autronexa supplies genuine surplus and refurbished MTL4013 units. Each unit is verified against OEM datasheet markings and part-number cross-reference before it is listed.

What condition will the MTL4013 arrive in?

Units are supplied in refurbished condition by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for current condition details on specific stock.

How fast can you ship the MTL4013?

Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability.

Does the MTL4013 work with an MTL4220 earth leakage detector?

Yes. Earth fault detection is enabled by connecting terminals 3 and 6 to an MTL4220 earth leakage detector. If you need to maintain isolation between the two channels, separate earth leakage detectors are required.

Related & compatible parts

MTL

SD32T3

Genuine MTL SD32T3 surge protection device with 3-terminal configuration and 10-year warranty. Verified surplus and refurbished units from…

In Stock

MTL

MTL3021

Genuine surplus MTL3021 switch/voltage change module for hazardous-area control, verified condition and practical sourcing support from Autronexa.

In Stock

MTL

MTL3045

Genuine surplus MTL3045 isolator passes 0-20mA to hazardous-area I/P converters and actuators with 800Ω load capability and verified…

In Stock

MTL

MTL3081

Genuine surplus MTL3081 thermocouple isolator with ±50mV input, non-energy-storing terminals, and optional burnout safety drive. Verified and ready…

In Stock

News & guides for MTL

View all articles

Request a quote for this part

Part number: MTL4013

We reply within one business day.

MTL4013 Quote reply within 1 business day