Set by a switch in

Manufacturer: MTL Part Number: MTL3081

Genuine surplus MTL3081 thermocouple isolator with ±50mV input, non-energy-storing terminals, and optional burnout safety drive. Verified and ready to source.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Number of channels One, fully floating
Input and output signal range 0 to ±50mV
Output impedance ≤250Ω
Transfer accuracy at 20°C 0.05% of reading (input ≥ ±10mV); ±5µV (input < ±10mV)
Response time Settles to within 10% of final value after typically 50ms
Power requirement 10mA maximum at 20 to 35V
Replaceable fuse 50mA, 5x20mm glass, semi-time-lag (M)
Weight 170g

Description

In process plants, the evolution from pneumatic controls to electronic monitoring brought a quiet challenge: how to safely pass a fragile thermocouple signal from a hazardous area into the safe area without compromising the loop. The MTL3081 answers that challenge. It is a single-channel, fully floating isolator that accepts a thermocouple or dc millivolt source in Zone 0, IIC, T4 or Div 1, Group A, and passes the signal to a receiving instrument in the safe area. For maintenance and procurement teams, a genuine surplus or refurbished unit offers a practical route to keep older loops running without waiting on OEM lead times.

What the MTL3081 Does in a Signal Loop

This unit takes a raw thermocouple or millivolt signal and isolates it, so the receiving instrument sees a clean, floating output. Its ±50mV input range covers all common thermocouple outputs, which means there are no calibration procedures to manage. The output impedance is ≤250Ω, and transfer accuracy at 20°C is 0.05% of reading for inputs of ±10mV or more, or ±5µV below that level. Because the input terminals are non-energy-storing, the unit can be installed in virtually any IS system without further certification, provided the loop open-circuit voltage does not exceed 28V.

Figure 1: Front view of the MTL MTL3081 Set by a switch in showing its physical design and enclosure.

Surplus Advantage for Legacy MTL Installations

Engineers who maintain MTL signal conditioners know that sourcing exact replacements can be slower than the plant can afford. Autronexa specializes in genuine surplus and refurbished automation components, and each unit is verified against OEM datasheet markings and part-number cross-reference before it is offered. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. This approach gives you a practical alternative to full OEM list pricing while keeping the signal integrity your loop depends on. Surplus and refurbished, ready to ship when you confirm availability.

Figure 2: Technical layout and connection details for the MTL MTL3081 Set by a switch in.

Selection and Sourcing Checks

Before ordering an unit, confirm the loop voltage and entity parameters. The input terminals are rated as non-energy-storing apparatus at ≤1.2V, ≤0.1A, ≤20µJ and ≤25mW, and FM maximum entity parameters are Voc = 1.2V, Isc = 22.5mA, Ca = 1000µF and La = 75mH. Also check the safety drive setting: a switch in the top of the unit selects upscale or downscale output on thermocouple burnout, or turns the drive off. The replaceable fuse is a 50mA, 5x20mm glass semi-time-lag type. Because lifecycle status is not stated in the available data, please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: MTL3081-datasheet.pdf

Frequently asked questions

Is this a genuine MTL3081, or a clone or copy?

Autronexa verifies each MTL3081 against OEM datasheet markings and part-number cross-reference before offering it. We source genuine surplus and refurbished units, not grey-market clones.

What condition will the MTL3081 arrive in?

Units are supplied as refurbished unless otherwise stated. Refurbished MTL3081 units are tested against OEM datasheet specifications and functionally verified by our sourcing team.

How fast can you ship the MTL3081?

Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability.

Does the MTL3081 work with existing IS loops?

The input terminals are non-energy-storing apparatus, so the MTL3081 can be connected without further certification into any IS loop with an open-circuit voltage not more than 28V. Confirm your loop parameters against the datasheet before installation.

Related & compatible parts

MTL

SD07X

Genuine surplus MTL SD07X surge protection device with <1ns response time and low resistance, verified and ready for…

In Stock

MTL

MTL4706

Genuine surplus MTL4706 barrier for 2-wire transmitters: ±2µA accuracy, 4/20mA output, verified condition and clear lead times from…

In Stock

MTL

ICC316

Genuine surplus MTL ICC316 indicating trip amplifier with 4-20mA or 1-5V input, LED display and relay outputs. Verified…

In Stock

MTL

SD16R

Genuine MTL SD16R surge protection device with 50MHz bandwidth and <1ns response time. Verified surplus and refurbished units…

In Stock

News & guides for MTL

View all articles

Request a quote for this part

Part number: MTL3081

We reply within one business day.

MTL3081 Quote reply within 1 business day