MTL MTL4706
Typically
Genuine surplus MTL4706 barrier for 2-wire transmitters: ±2µA accuracy, 4/20mA output, verified condition and clear lead times from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Channel numbers | 1 and 2 |
|---|---|
| Safety description | 28V, 300Ω, 93mA |
| Output current | 4/20mA |
| Voltage for Tx & lines | ≥16V at 20mA |
| Load resistance | 250Ω ± 5% |
| Accuracy | ±2µA |
| Fuse rating | 50mA |
| Supply voltage range | 20 to 26.8V on bussed-power backplanes; 20 to 35.0V on general-purpose or custom backplanes |
| Supply current (total) | 100mA maximum at 20mA with 20V supply; 80mA typical at 20mA with 24V supply |
| Power supply fuse | 250mA |
Description
How do you keep two hazardous-area 4/20mA loops powered when a barrier fails and OEM lead times stretch? The MTL4706 from MTL is a 2-channel electronic, over-volt protected barrier built for exactly that job. It energises conventional and smart 2-wire transmitters, with one channel powering each loop. Autronexa supplies genuine surplus and refurbished units with verified condition and clear lead times.
What this unit Does in a 4/20mA Loop
this unit sits between the safe area and the hazardous area. Each of its two channels typically powers a single 2-wire transmitter, so one barrier can drive two hazardous-area devices. A built-in floating dc power supply provides a high voltage output for the transmitters, delivering at least 16V at 20mA to the transmitter and lines. The output current is 4/20mA, and the load resistance is 250Ω ± 5%. The patented circuit design holds accuracy to ±2µA under all conditions, which matters when a control system relies on a clean, repeatable signal. The unit can also operate from bussed power.

Key Specifications Buyers Should Check
The safety description for this barrier is 28V, 300Ω, 93mA, and the fuse rating is 50mA. Supply voltage range is 20 to 26.8V on bussed-power backplanes, limited by the on-board protection circuit, or 20 to 35.0V on general-purpose or custom backplanes. Total supply current is 100mA maximum at 20mA with a 20V supply, and 80mA typical at 20mA with a 24V supply. The power supply fuse is 250mA, and matched power is 0.65W. For single-channel earth-return cable runs, the maximum cable parameters are 0.13µF capacitance and 4.2mH inductance under BASEEFA group IIC, or 0.14µF and 4.23mH under FM groups A and B. Buyers should confirm the exact revision and any accessory needs before ordering.

Why Genuine Surplus Makes Sense for This Barrier
When a barrier is hard to source new, a verified surplus or refurbished this unit keeps the loop running without a long OEM wait. Autronexa checks each unit against OEM datasheet markings and part-number cross-reference, then confirms condition and current availability before you commit. That practical approach suits maintenance teams replacing a single failed channel as much as projects building spares stock. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is the MTL4706 a genuine MTL barrier or a clone?
Autronexa verifies each MTL4706 against OEM datasheet markings and part-number cross-reference before it is offered. Units are genuine surplus or professionally refurbished, not grey-market copies.
What condition will the MTL4706 arrive in?
Autronexa supplies the MTL4706 as refurbished by default, tested against OEM datasheet specifications and functionally verified by the sourcing team. Confirm the condition grade with Autronexa when you request a quote.
How fast can Autronexa ship the MTL4706?
Lead time depends on current stock, so contact Autronexa for the present lead time on the MTL4706. Surplus and refurbished units are typically ready to ship once condition and availability are confirmed.
Can the MTL4706 drive two hazardous-area transmitters?
Yes. The MTL4706 is a 2-channel barrier, and each loop is typically powered by a single channel, so one unit can drive two hazardous-area devices. It delivers at least 16V at 20mA to the transmitter and lines.
Related & compatible parts
MTL
MTL4014
Genuine surplus MTL4014 switch input relay for hazardous-area circuits, with line fault detection and 2ms response. Verified condition…
MTL
SD07X
Genuine surplus MTL SD07X surge protection device with <1ns response time and low resistance, verified and ready for…
MTL
MTL4646Y
Genuine surplus MTL4646Y controller drives current/pressure converters with HART support and 800Ω load capacity. Verified condition, ready to…
MTL
SD32T3
Genuine MTL SD32T3 surge protection device with 3-terminal configuration and 10-year warranty. Verified surplus and refurbished units from…
News & guides for MTL
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…