MTL I/O & Function Modules

MTL MTL5041

Located

Manufacturer: MTL Part Number: MTL5041

Genuine surplus MTL5041 isolator: fully-floating 2-wire transmitter supply with 4 to 20mA repeat for safe-area loads. Verified condition, ready to ship.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Number of channels One
Transmitter location Zone 0, IIC, T4–6 hazardous area if suitably certified; Div. 1, Group A
Safe-area output signal range 4 to 20mA
Safe-area over/under-range 0 to 24mA
Safe-area load resistance 0 to 1kΩ
Safe-area circuit output resistance >2MΩ
Safe-area circuit ripple <125µA peak-to-peak
Hazardous-area input signal range 0 to 24mA (including over-range)
Transmitter voltage 16.5V at 20mA
Supply voltage 20 to 35V dc

Description

The MTL5041 from MTL is a single-channel signal isolator that provides a fully-floating dc supply for a conventional 2-wire 4 to 20mA transmitter in a hazardous area and repeats the current into a floating safe-area circuit. Engineers specifying this unit get galvanic separation between field and control room without a separate power supply. Autronexa supplies genuine surplus and refurbished this unit units with verified condition and practical sourcing support.

What Does this unit Do in a 2-Wire Loop?

This unit sits between a hazardous-area transmitter and a safe-area load. It energises the transmitter with a floating supply and repeats the loop current in a separate floating circuit. The hazardous-area input accepts 0 to 24mA including over-range, while the safe-area output delivers 4 to 20mA with over/under-range of 0 to 24mA. A safe-area load resistance of 0 to 1kΩ suits most receiving instruments. The safe-area circuit output resistance exceeds 2MΩ, and ripple stays below 125µA peak-to-peak. A green LED gives power indication for quick loop checks.

Figure 1: Front view of the MTL MTL5041 Located showing its physical design and enclosure.

Why Choose Genuine Surplus for This Isolator?

When an this unit fails, the priority is a verified replacement, not a long OEM lead time. Surplus and refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. That means you can confirm the 16.5V transmitter voltage at 20mA and the 4 to 20mA transfer before installation. For maintenance teams, genuine surplus removes the guesswork of grey-market clones. Autronexa focuses on Allen-Bradley, Bently Nevada, Siemens, Schneider and MTL families, so the sourcing conversation stays technical.

Figure 2: Technical layout and connection details for the MTL MTL5041 Located.

Which Installation Details Should You Verify?

This unit operates from a 20 to 35V dc supply and draws 70mA at 24V with a 20mA signal. Maximum power dissipation within the unit is 1.2W at 24V. Transfer accuracy at 20°C is better than 20µA, typically 5µA, with temperature drift below 1µA/°C. Response time settles to within 10% of final value within 250µs. The safety description is 28V, 300Ω, 93mA; Um = 250V rms or dc. Before ordering, confirm the hazardous-area certification suits your Zone 0, IIC, T4–6 or Div. 1, Group A location. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is the MTL5041 a genuine MTL unit or a clone?

Autronexa verifies every MTL5041 against OEM datasheet markings and part-number cross-reference before it enters stock. Units are genuine surplus or professionally refurbished, not grey-market copies.

What condition will the MTL5041 arrive in?

The MTL5041 is supplied as refurbished unless otherwise stated. Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch.

How fast can you ship the MTL5041?

Lead time depends on current stock. Contact Autronexa with your MTL5041 requirement for verified condition and current availability.

Does the MTL5041 suit a Zone 0 hazardous-area transmitter?

Yes, the MTL5041 supports a transmitter located in Zone 0, IIC, T4–6 hazardous area if suitably certified, and Div. 1, Group A hazardous locations. Confirm your certification requirements with Autronexa.

Related & compatible parts

MTL

SD07R

Genuine MTL SD07R surge protector with 50MHz bandwidth. Verified surplus stock, tested and ready for your signal line…

In Stock

MTL

MTL3021

Genuine surplus MTL3021 switch/voltage change module for hazardous-area control, verified condition and practical sourcing support from Autronexa.

In Stock

MTL

MTL3013

Genuine surplus MTL3013 two-channel switch/proximity detector relay for hazardous-area sensors, verified and ready to ship from Autronexa.

In Stock

MTL

MTL5541

Genuine surplus MTL5541 repeater power supply for 4-20mA transmitters in hazardous areas, with HART support and SIL2 capability.…

In Stock

News & guides for MTL

View all articles

Request a quote for this part

Part number: MTL5041

We reply within one business day.

MTL5041 Quote reply within 1 business day