Technical specifications

Number of channels One, fully floating
Input voltage 20 to 35V dc
Maximum input current 130mA (MTL3021)
Maximum output voltage 28V from 300Ω, current limited at 65mA (MTL3021)
Output ripple <0.5% of maximum output, peak-to-peak
Response time Settles to within 10% of final value after typically 10ms
Safety description 28V, 300Ω, 93mA, Um = 250V rms or dc (MTL3021)
Weight 140g

Description

When a hazardous-area solenoid or alarm must be controlled from a safe-area switch, the MTL3021 switch/voltage change module provides the isolated link. Autronexa supplies genuine surplus and refurbished units with verified condition, giving maintenance teams a practical alternative to long OEM lead times.

What the MTL3021 Does in a Control Loop

This unit lets a device in a hazardous area be controlled by a switch or voltage change in the safe area. It drives any certified intrinsically safe, low-power load such as a solenoid or alarm, and also non-energy-storing simple apparatus like an LED. Because the input/output isolation allows field cables to be earthed, the control switch can be connected into either side of the 24V dc supply circuit. The unit has one fully floating channel, so the load circuit remains independent of the control circuit. This arrangement suits panels where field wiring must be earthed for noise or safety reasons without compromising the control path.

Figure 1: Front view of the MTL MTL3021 Switch or voltage change showing its physical design and enclosure.

Surplus Advantage for This unit

unit modules are often requested as replacements in existing intrinsically safe loops. Autronexa holds genuine surplus and refurbished units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. For this model, the output ripple is held to <0.5% of maximum output, peak-to-peak, a figure we confirm during functional checks. Refurbished units are inspected for fuse condition and terminal integrity before dispatch. Because these are surplus and refurbished, ready to ship stock can shorten the wait compared with ordering new from the OEM. Our team also helps verify the exact revision and safety description against your loop documentation.

Figure 2: Technical layout and connection details for the MTL MTL3021 Switch or voltage change.

Sourcing the Right unit for Your Loop

Before ordering, confirm the safety description required for your application. This unit carries a safety description of 28V, 300Ω, 93mA, Um = 250V rms or dc, and FM entity parameters of Voc = 28V, Isc = 93mA, Ca = 0.13µF, La = 4.0mH. Check that your hazardous-area certification matches the load location, including Zone 0, IIC, T4–6 or Div 1, Group A. Also verify the input voltage range of 20 to 35V dc and the maximum input current of 130mA. The replaceable fuse is a 200mA, 5x20mm glass type to DIN 41571 sht.2, semi-time-lag (M). Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: MTL3021-datasheet.pdf

Frequently asked questions

Is this a genuine MTL MTL3021, or a clone?

Autronexa verifies units against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished MTL3021 modules, not grey-market copies.

What condition will the MTL3021 arrive in?

Units are supplied as refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Fuse condition and terminal integrity are checked before dispatch.

How fast can you ship the MTL3021?

Contact Autronexa for current lead time. Surplus and refurbished, ready to ship stock can shorten the wait compared with ordering new from the OEM.

Does the MTL3021 work with my existing intrinsically safe loop?

The MTL3021 has one fully floating channel and an input voltage range of 20 to 35V dc. Confirm your loop safety description matches 28V, 300Ω, 93mA, Um = 250V rms or dc before ordering.

Related & compatible parts

MTL

MTL3011

Genuine surplus MTL3011 switch input isolator with relay output, line-fault detection and phase-reverse control. Verified condition, ready to…

In Stock

MTL

SD32X

Genuine MTL SD32X surge protection device with 32Vdc nominal voltage and 400 mA nominal current. Verified surplus stock…

In Stock

MTL

SLP32D

Genuine surplus MTL SLP32D surge protection module for two process loops, with 20kA hybrid circuitry and 24V nominal…

In Stock

MTL

MTL3081

Genuine surplus MTL3081 thermocouple isolator with ±50mV input, non-energy-storing terminals, and optional burnout safety drive. Verified and ready…

In Stock

News & guides for MTL

View all articles

Request a quote for this part

Part number: MTL3021

We reply within one business day.

MTL3021 Quote reply within 1 business day