MTL MTL3021
Switch or voltage change
Genuine surplus MTL3021 switch/voltage change module for hazardous-area control, verified condition and practical sourcing support from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Number of channels | One, fully floating |
|---|---|
| Input voltage | 20 to 35V dc |
| Maximum input current | 130mA (MTL3021) |
| Maximum output voltage | 28V from 300Ω, current limited at 65mA (MTL3021) |
| Output ripple | <0.5% of maximum output, peak-to-peak |
| Response time | Settles to within 10% of final value after typically 10ms |
| Safety description | 28V, 300Ω, 93mA, Um = 250V rms or dc (MTL3021) |
| Weight | 140g |
Description
When a hazardous-area solenoid or alarm must be controlled from a safe-area switch, the MTL3021 switch/voltage change module provides the isolated link. Autronexa supplies genuine surplus and refurbished units with verified condition, giving maintenance teams a practical alternative to long OEM lead times.
What the MTL3021 Does in a Control Loop
This unit lets a device in a hazardous area be controlled by a switch or voltage change in the safe area. It drives any certified intrinsically safe, low-power load such as a solenoid or alarm, and also non-energy-storing simple apparatus like an LED. Because the input/output isolation allows field cables to be earthed, the control switch can be connected into either side of the 24V dc supply circuit. The unit has one fully floating channel, so the load circuit remains independent of the control circuit. This arrangement suits panels where field wiring must be earthed for noise or safety reasons without compromising the control path.

Surplus Advantage for This unit
unit modules are often requested as replacements in existing intrinsically safe loops. Autronexa holds genuine surplus and refurbished units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. For this model, the output ripple is held to <0.5% of maximum output, peak-to-peak, a figure we confirm during functional checks. Refurbished units are inspected for fuse condition and terminal integrity before dispatch. Because these are surplus and refurbished, ready to ship stock can shorten the wait compared with ordering new from the OEM. Our team also helps verify the exact revision and safety description against your loop documentation.

Sourcing the Right unit for Your Loop
Before ordering, confirm the safety description required for your application. This unit carries a safety description of 28V, 300Ω, 93mA, Um = 250V rms or dc, and FM entity parameters of Voc = 28V, Isc = 93mA, Ca = 0.13µF, La = 4.0mH. Check that your hazardous-area certification matches the load location, including Zone 0, IIC, T4–6 or Div 1, Group A. Also verify the input voltage range of 20 to 35V dc and the maximum input current of 130mA. The replaceable fuse is a 200mA, 5x20mm glass type to DIN 41571 sht.2, semi-time-lag (M). Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine MTL MTL3021, or a clone?
Autronexa verifies units against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished MTL3021 modules, not grey-market copies.
What condition will the MTL3021 arrive in?
Units are supplied as refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Fuse condition and terminal integrity are checked before dispatch.
How fast can you ship the MTL3021?
Contact Autronexa for current lead time. Surplus and refurbished, ready to ship stock can shorten the wait compared with ordering new from the OEM.
Does the MTL3021 work with my existing intrinsically safe loop?
The MTL3021 has one fully floating channel and an input voltage range of 20 to 35V dc. Confirm your loop safety description matches 28V, 300Ω, 93mA, Um = 250V rms or dc before ordering.
Related & compatible parts
MTL
MTL3011
Genuine surplus MTL3011 switch input isolator with relay output, line-fault detection and phase-reverse control. Verified condition, ready to…
MTL
SD32X
Genuine MTL SD32X surge protection device with 32Vdc nominal voltage and 400 mA nominal current. Verified surplus stock…
MTL
SLP32D
Genuine surplus MTL SLP32D surge protection module for two process loops, with 20kA hybrid circuitry and 24V nominal…
MTL
MTL3081
Genuine surplus MTL3081 thermocouple isolator with ±50mV input, non-energy-storing terminals, and optional burnout safety drive. Verified and ready…
News & guides for MTL
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…