MTL SLP32D
Module provides full hybrid surge protection
Genuine surplus MTL SLP32D surge protection module for two process loops, with 20kA hybrid circuitry and 24V nominal voltage.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Nominal voltage | 24V |
|---|---|
| Rated voltage (MCOV) | 32V |
| Nominal current | 1.50A |
| Maximum discharge current (8/20µs) | 20kA |
| Nominal discharge current (8/20µs) | 3kA |
| Bandwidth | 50MHz |
| Capacitance (line to line) | 60pF |
| Leakage current | <1µA @ working voltage |
| Degree of protection | IP20 |
| Mounting | T-section DIN-rail (35 x 15mm rail) |
Description
The MTL SLP32D is a DIN-rail surge protection module from the SLP range that provides full hybrid protection for two process loops or one 4-wire circuit. It suits maintenance and procurement teams that need genuine surplus or refurbished automation parts without long OEM lead times. Autronexa supplies verified units with clear condition notes.
What this module Does in a Process Loop
The module sits between field wiring and your control equipment. Its multi-stage hybrid circuit combines solid-state electronics with a gas-filled discharge tube, diverting surge currents safely to earth and clamping output voltages to safe levels. Because the circuit adds only a tiny voltage drop, signals pass with very little attenuation. This module handles two loops in one case, so panel space stays efficient. One simple manual action clamps the module onto T-section DIN rail and automatically provides a high-integrity earth connection.

Key Specifications at a Glance
this module is rated for a 24V nominal voltage and a 32V maximum continuous operating voltage. It carries a nominal current of 1.50A and a maximum discharge current of 20kA (8/20µs). Line-to-line capacitance is 60pF, which supports high-bandwidth communication circuits. Leakage current stays below 1µA at working voltage, so the module does not disturb sensitive analogue signals. The response time is under 1ns, and the case meets UL94-V0 flammability. EMC compliance covers BS EN 60950-1:2006+A12:2011, BS EN 61326-1:2006 and BS EN 61010-1:2010.

How It Compares with Alternatives
When you compare this module with a standard single-loop surge protector, the two-loop density and 20kA rating stand out. Against a basic terminal-block protector, the hybrid GDT and solid-state circuit gives faster response and lower line resistance. Against a brand-new OEM order, genuine surplus and refurbished stock can shorten the wait. Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it ships.
Sourcing this module with Confidence
Buyers should confirm the exact model and revision, the 24V nominal rating, and whether the application needs two loops or one 4-wire circuit. Surplus and refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is the MTL SLP32D a genuine module or a clone?
Autronexa verifies every MTL SLP32D against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished units, not grey-market copies.
What condition will the SLP32D arrive in?
The MTL SLP32D is supplied as refurbished stock unless otherwise stated. Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch.
How fast can Autronexa ship the SLP32D?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability of the MTL SLP32D.
Does the SLP32D suit high-bandwidth signal circuits?
Yes. The MTL SLP32D has a bandwidth of 50MHz and 60pF line-to-line capacitance, so it is designed for high-bandwidth, low-resistance applications.
Related & compatible parts
MTL
ICC312
Genuine surplus MTL ICC312 repeater power supply with dual isolated outputs, line-fault detection, and 20-35V dc operation for…
MTL
MTL3011
Genuine surplus MTL3011 switch input isolator with relay output, line-fault detection and phase-reverse control. Verified condition, ready to…
MTL
MTL4015
Genuine surplus MTL4015 switch/proximity detector for hazardous areas, with dual relay outputs and verified condition from Autronexa.
MTL
MTL3042
Genuine surplus MTL3042 controller isolator for 4-20mA I/P converters. Verified condition, clear lead times, and practical sourcing help…
News & guides for MTL
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…