MTL ICC312
Repeater Power Supply: ICC312
Genuine surplus MTL ICC312 repeater power supply with dual isolated outputs, line-fault detection, and 20-35V dc operation for 2-wire transmitters.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Input signal | 4 to 20mA |
|---|---|
| Number of output channels | Two |
| Isolation | 1500V dc/ac between input, output 1, output 2 and power supply |
| Power supply | 20 to 35V dc |
| Load resistance | 0 to 1kΩ |
| Transfer accuracy | Better than 20μA for both outputs |
| Response time | 80ms to 90% of span; 280ms to 99.9% of span |
| Ambient temperature limits | -20°C to +55°C operating; -40°C to +80°C storage |
Description
The MTL ICC312 repeater power supply is a DIN-rail isolator that energises a 2-wire 4-20mA transmitter and transfers its current to two separate isolated output circuits. Maintenance teams and integrators choose genuine surplus or refurbished ICC312 units to replace failed isolators without waiting on OEM lead times. Autronexa supplies verified surplus and refurbished MTL components with clear condition reports and practical sourcing support.
What This unit Does in a 4-20mA Loop
This unit sits between a field transmitter and the receiving system. It provides a fully isolated dc supply for the transmitter while repeating the 4-20mA signal to two independent outputs, each capable of driving loads up to 1kΩ. Three-port isolation separates input, outputs, and power supply at 1500V dc/ac. An open-collector line-fault detection output activates an alarm when the input cable breaks. The module mounts directly onto T- or G-section DIN-rail to DIN46277 and accepts 2.5mm conductors in a 40mm polyamide casing.

Key Specifications That Matter on Site
This unit operates from a 20 to 35V dc power supply and delivers a minimum of 20V at 20mA to the transmitter. Transfer accuracy is better than 20μA for both outputs, with a temperature drift below 1μA/°C. Response time reaches 90% of span in 80ms and 99.9% in 280ms, so the loop reacts quickly to process changes. The line-fault detection transistor switches ON when input current exceeds 1mA and OFF below 0.2mA, with a maximum permitted voltage of 26V dc and maximum ON voltage of 1V. Ambient operating limits are -20°C to +55°C, with storage from -40°C to +80°C at 5 to 95% RH non-condensing.

Why Genuine Surplus Makes Sense for This Module
When an unit fails, the priority is a verified replacement that matches the original wiring and isolation scheme. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus stock often shortens the wait compared with factory lead times, and This unit’s standard DIN-rail format means no re-engineering is needed. Autronexa focuses on genuine parts, verified, so you can trust the module you install.
Sourcing the Right unit for Your Panel
Before ordering, confirm the exact model and terminal configuration, especially whether your loop uses terminals 7&8 for a 2-wire transmitter or terminals 8&9 for a current source. Check that the power supply falls within 20 to 35V dc and that output loads stay at or below 1kΩ. Ask for the condition grade and any test documentation. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine MTL ICC312 or a clone?
Autronexa verifies each ICC312 against OEM datasheet markings and part-number cross-reference before listing. We supply genuine surplus and refurbished units, not copies.
What condition will the ICC312 arrive in?
Our default condition is refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are graded and described before shipment.
How fast can you ship the ICC312?
Lead time depends on current stock. Contact Autronexa for the latest availability and dispatch estimate for your required quantity.
Does the ICC312 work with my existing 4-20mA loop?
The ICC312 provides two isolated outputs from one 4-20mA transmitter, with 1500V dc/ac isolation and loads up to 1kΩ. Confirm your terminal wiring and power supply range with our team before ordering.
Related & compatible parts
MTL
ICC212
Genuine MTL ICC212 repeater power supply and isolating driver with three-port galvanic isolation, verified for smart transmitter loops.
MTL
MTL3081
Genuine surplus MTL3081 thermocouple isolator with ±50mV input, non-energy-storing terminals, and optional burnout safety drive. Verified and ready…
MTL
MTL3013
Genuine surplus MTL3013 two-channel switch/proximity detector relay for hazardous-area sensors, verified and ready to ship from Autronexa.
MTL
MTL4521L
Genuine surplus MTL4521L loop-powered solenoid/alarm driver for Zone 0 IIC hazardous areas, verified and ready to ship from…
News & guides for MTL
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…