MTL MTL3011
Switch located
Genuine surplus MTL3011 switch input isolator with relay output, line-fault detection and phase-reverse control. Verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Number of channels | One, fully floating |
|---|---|
| Voltage applied to sensor | 7.7 to 9.0V dc from 1kΩ |
| Output closed | If >2.1mA (<2kΩ) in sensor circuit |
| Output open | If <1.2mA (>10kΩ) in sensor circuit |
| Hysteresis | 200µA (650Ω) nominal |
| Response time | 1ms typical |
| Contact rating | 200V, 0.5A, 10VA (ac); 200V, 0.5A, 10W (dc) |
| Contact life expectancy | 0.75 x 106 operations at max. load |
| Power requirement | 25mA typical at 24V |
| Weight | 140g |
Description
The MTL3011 is an MTL switch input isolator that lets a safe-area load be controlled by a proximity detector or switch located in a hazardous area, and it provides a relay output for general use. For maintenance and procurement teams, a genuine surplus unit keeps a hazardous-area loop running without waiting on a full OEM lead time.
What the MTL3011 Does in a Hazardous-Area Loop
This unit carries one fully floating channel and places the switch in Zone 0, IIC, T6 hazardous areas and Div 1, Group A locations. It applies 7.7 to 9.0V dc to the sensor from 1kΩ, so the detector sees a stable supply across the loop. The output closes above 2.1mA in the sensor circuit and opens below 1.2mA, with 200µA (650Ω) nominal hysteresis that keeps chatter out of the relay. Because the channel is fully floating, one unit covers a range of loop layouts, which reduces the number of variants a maintenance store must hold.

Relay Output, Line-Fault Detection and Phase Reverse
This unit relay output is rated 200V, 0.5A, 10VA (ac) and 200V, 0.5A, 10W (dc), with 60V individual maxima for USA resistive loads. Response time is 1ms typical, so the relay follows the process without adding measurable delay. Built-in line-fault detection opens the output on a broken line below 100µA or a shorted line above 6.5mA, which turns a hidden cable fault into a clear alarm state. A switch on top of the unit reverses operation, so either sensor state can signal an alarm without rewiring. Contact life expectancy is 0.75 x 106 operations at maximum load; reactive loads must be adequately suppressed to protect the light-duty contacts.

Surplus Advantage for This Model
A genuine surplus or refurbished unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch. That matters on a shunt-diode safety barrier, where an unverified substitute can compromise the loop. Each unit is checked for relay operation, line-fault behaviour and phase-reverse function, and the replaceable 50mA fuse is confirmed present. For plants holding spares of this family, a verified surplus unit is a practical way to restore a loop while avoiding the cost and delay of a new-build order.
Sourcing the Right Variant
Confirm the channel count, output type and hazardous-area certification against your loop drawing before ordering. This unit draws 25mA typical at 24V and weighs 140g, so it fits existing panel space. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine MTL MTL3011, or a clone?
Every MTL3011 we supply is checked against OEM datasheet markings and part-number cross-reference before it is listed. We do not sell copies or unverified substitutes.
What condition will the MTL3011 arrive in?
Units are supplied refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask us for the current condition grade on the unit in stock.
How fast can you ship the MTL3011?
Contact Autronexa for current lead time. Surplus and refurbished stock is ready to ship once condition is confirmed against your order.
Does the MTL3011 relay output suit my load?
The relay contacts are rated 200V, 0.5A, 10VA (ac) and 200V, 0.5A, 10W (dc), with 60V individual maxima for USA resistive loads. Reactive loads must be adequately suppressed to protect the light-duty contacts.
Related & compatible parts
MTL
MTL3045
Genuine surplus MTL3045 isolator passes 0-20mA to hazardous-area I/P converters and actuators with 800Ω load capability and verified…
MTL
MTL4016
Genuine surplus MTL4016 interface: two channels, relay outputs, line fault detection, and hazardous-area certification for Zone 0/Div.1.
MTL
MTL3081
Genuine surplus MTL3081 thermocouple isolator with ±50mV input, non-energy-storing terminals, and optional burnout safety drive. Verified and ready…
MTL
SLP16D
Genuine surplus MTL SLP16D modules provide hybrid surge protection for two process loops, with 20kA surge current and…
News & guides for MTL
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…