MTL MTL3041
Transmitter
Genuine surplus MTL3041 transmitter isolator with fully floating 17.5V loop supply and 4 to 20mA signal range, verified and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Number of channels | One, fully floating |
|---|---|
| Input and output signal range | 4 to 20mA (0 to 20mA full range) |
| Voltage available for transmitter and lines | 17.5V minimum at 20mA |
| Maximum open-circuit voltage | 28V |
| Safe-area circuit load resistance | 0 to 800Ω |
| Safe-area circuit ripple | <10µA peak-to-peak |
| Transfer accuracy at 20°C | Better than 20µA |
| Temperature drift | <1µA/°C |
| Replaceable fuse | 125mA, 5x20mm glass, semi-time-lag (M) |
| Weight | 160g |
Description
The MTL3041 is a fully floating transmitter isolator that energises a 2-wire 4 to 20mA transmitter in a hazardous area and repeats the current accurately in a safe-area circuit. Maintenance teams and integrators choose genuine surplus or refurbished units of this model to keep loop availability high without waiting on OEM lead times.
What the MTL3041 Does in a Loop
This unit provides a fully-floating dc supply for a 2-wire, 4 to 20mA transmitter in a hazardous area. It repeats the current accurately in another floating circuit to drive a safe-area load. The 17.5V output at 20mA is more than sufficient for normal transmitter loops. Because the field circuit floats, field cables can be earthed either intentionally or in error. The isolation of the safe-area circuit from the 24V dc supply lets systems be wired to eliminate measurement errors from voltage drops in shared cables. It also solves the problem of feeding control computers connected independently to earth, as some makers demand. The transformer-coupled circuit chops the 4 to 20mA current directly, eliminating high-stability resistors and supporting long-term stability. For smart transmitters, the MTL3046B is the recommended variant.

Technical Specs That Matter
Three published values shape day-to-day performance. Safe-area circuit ripple is <10µA peak-to-peak, keeping the repeated signal clean for downstream loads. Temperature drift is <1µA/°C, so accuracy holds across normal plant temperature swings. The maximum open-circuit voltage is 28V, a figure worth confirming against your hazardous-area certification. The safe-area circuit load resistance range is 0 to 800Ω, and transfer accuracy at 20°C is better than 20µA. A replaceable 125mA fuse protects the unit. This unit weighs 160g.

Surplus Advantage for This Model
This unit is a regularly requested genuine unit in the MTL isolator family. Autronexa supplies surplus and refurbished units tested against OEM datasheet specifications and functionally verified by our sourcing team. That means you can match the exact model, confirm condition, and get a clear lead time rather than an open-ended OEM backorder. Each unit is checked for the published ripple, drift and open-circuit voltage behaviour before dispatch. If your loop uses a smart transmitter, confirm the MTL3046B alternative with our team first.
Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine MTL MTL3041, or a clone?
Autronexa verifies each MTL3041 against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished units only.
What condition will the MTL3041 arrive in?
Units are supplied refurbished as standard, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade.
How fast can you ship the MTL3041?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability.
Does the MTL3041 suit a smart transmitter?
The MTL3041 is intended for standard 2-wire 4 to 20mA transmitters. For smart transmitters, the MTL3046B is the recommended variant in the MTL range.
Related & compatible parts
MTL
SD32X
Genuine MTL SD32X surge protection device with 32Vdc nominal voltage and 400 mA nominal current. Verified surplus stock…
MTL
MTL3042
Genuine surplus MTL3042 controller isolator for 4-20mA I/P converters. Verified condition, clear lead times, and practical sourcing help…
MTL
MTL3073
Genuine surplus MTL3073 temperature converter for hazardous-area sensors, verified and ready to ship from Autronexa.
MTL
IOP32
Genuine MTL IOP32 surge protector for single-loop solenoid drive circuits, verified surplus and refurbished with clear lead times…
News & guides for MTL
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…
