MTL MTL3073
Sensor mounted
Genuine surplus MTL3073 temperature converter for hazardous-area sensors, verified and ready to ship from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Input signal range | –75 to +75mV, or 0 to 400Ω |
|---|---|
| Input signal span | 3 to 150mV, or 10 to 400Ω |
| Output range | 4 to 20mA nominal (direct or reverse) |
| Maximum load resistance | 600Ω |
| Isolation | 250V ac between safe- and hazardous-area circuits |
| Calibration accuracy (at 20°C) | mV/THC: ±15µV or ±0.05% of input value; RTD: ±80mΩ; Output: ±11µA |
| Cold junction compensation error | ≤1.0°C |
| Weight | 170g |
Description
The MTL3073 is a sensor-mounted temperature converter that takes a low-level DC signal from a hazardous-area temperature sensor and converts it to a 4/20mA output for safe-area loads. For maintenance and procurement teams, a genuine surplus or refurbished unit offers a practical alternative to long OEM lead times. Autronexa supplies verified MTL3073 modules with clear condition notes and sourcing support.
What This unit Does in Your Loop
This unit accepts inputs from eight thermocouple types and 2-, 3-, and 4-wire RTDs. It provides automatic or selectable cold-junction compensation, with an integral CJC sensor for thermocouple inputs. Configuration is carried out via a PC using the PCL45 interface and PCS45 software. The module delivers a 4 to 20mA nominal output, direct or reverse, and supports a maximum load resistance of 600Ω. A single green LED provides power and status indication. The default configuration is a Type K thermocouple with linearisation enabled, 0 to 250°C output span, and upscale open-circuit alarm. These defaults suit many common monitoring setups, while software-selectable features allow ranging, linearisation, monitoring, testing, and tagging.

Technical Specs That Matter for Sensor Matching
Three specifications are particularly useful when checking This unit against your sensor and loop. First, the input signal range is –75 to +75mV or 0 to 400Ω, with a span of 3 to 150mV or 10 to 400Ω. This covers a broad set of thermocouple and RTD spans. Second, calibration accuracy at 20°C is ±15µV or ±0.05% of input value for mV/THC inputs, whichever is greater, and ±80mΩ for RTD inputs; the output accuracy is ±11µA. Third, isolation is rated at 250V AC between safe- and hazardous-area circuits, and the safety description for terminals 5 and 6 allows connection into any IS loop with an open-circuit voltage not more than 10V. These figures help you confirm compatibility before committing a spare to a critical loop.

Surplus Advantage: Why a Verified unit Makes Sense
Autronexa specialises in genuine surplus and professionally refurbished automation components. A refurbished unit is tested against OEM datasheet specifications and functionally verified by our sourcing team. That means you get a module with documented condition, not an unknown unit from a general reseller. For legacy MTL3000 series installations, surplus stock can bridge the gap when a new purchase involves extended lead times. Because This unit weighs 170g and uses a replaceable 100mA fuse, it is straightforward to store and maintain as a spare. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is the MTL3073 a genuine MTL module or a clone?
Autronexa verifies each MTL3073 against OEM datasheet markings and part-number cross-reference before it is listed. We supply genuine surplus and refurbished units, not copies.
What condition will the MTL3073 arrive in?
Our default condition for this model is refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact us for the specific condition of current stock.
How fast can you ship the MTL3073?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability.
Does the MTL3073 work with my existing thermocouple or RTD?
The MTL3073 accepts eight thermocouple types and 2-, 3-, and 4-wire RTDs. Input range is –75 to +75mV or 0 to 400Ω. Check your sensor type and span against these figures, or ask our team for help.
Related & compatible parts
MTL
MTL3042
Genuine surplus MTL3042 controller isolator for 4-20mA I/P converters. Verified condition, clear lead times, and practical sourcing help…
MTL
SD32
Genuine MTL SD32 surge protector with 32 VDC / 22 VAC rating, 250 mA nominal current, and fuse…
MTL
ICC212
Genuine MTL ICC212 repeater power supply and isolating driver with three-port galvanic isolation, verified for smart transmitter loops.
MTL
MTL4646Y
Genuine surplus MTL4646Y controller drives current/pressure converters with HART support and 800Ω load capacity. Verified condition, ready to…
News & guides for MTL
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…