MTL SD32
Circuit Protection
Genuine MTL SD32 surge protector with 32 VDC / 22 VAC rating, 250 mA nominal current, and fuse disconnect. Verified surplus and refurbished units from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Nominal voltage (Un) | 32 VDC, 22 VAC |
|---|---|
| Nominal current (In) | 250 mA |
| Series resistance | 4.2 per line |
| Max. leakage current | 5 µA |
| Rated voltage (MCOV) | 36 |
| Voltage protection level @1kV/µs | <45 V |
| Residual voltage @ In | 60 V |
| Bandwidth | 25 kHz |
| Special feature | Fuse disconnect |
| Dimensions (LxWxH) | 0.7 cm x 9.9 cm x 10.13 cm |
Description
A field instrument on a 32 VDC signal line takes a transient hit, and the downstream electronics are at risk. The MTL SD32 surge protector is built to sit on that line and divert the surge before it reaches sensitive equipment. Autronexa supplies genuine surplus and refurbished this unit units with verified condition and practical sourcing support.
What the MTL this unit Surge Protector Does
this unit is a surge protector from MTL instruments, rated for 32 VDC and 22 VAC nominal voltage. It carries a nominal current of 250 mA and presents a series resistance of 4.2 per line. The maximum leakage current is 5 µA, so it stays effectively transparent to the signal under normal conditions. A fuse disconnect feature is built in, which lets technicians isolate the protected circuit during maintenance without pulling the module. The compact housing measures 0.7 cm x 9.9 cm x 10.13 cm and weighs 0.07 kg, so it fits into tight panel spaces where a full-size protector will not go.

Protection Performance Buyers Should Verify
Protection level is the number that matters when specifying a surge protector. This unit has a voltage protection level of less than 45 V at 1 kV/µs, and a residual voltage of 60 V at nominal current. The rated voltage, or MCOV, is 36. These figures describe how much let-through voltage the downstream device will see during a surge event. The 25 kHz bandwidth shows the protector is intended for signal lines rather than high-frequency data buses. Buyers should match these values against the withstand rating of the equipment being protected before ordering.
Why Genuine Surplus Makes Sense for This Model
MTL surge protectors are often specified into long-life process installations, and when one fails, the priority is a correct replacement rather than a new-production unit. Autronexa stocks genuine surplus and refurbished this unit protectors that are tested against OEM datasheet specifications and functionally verified before dispatch. That gives maintenance teams a practical alternative to waiting on factory lead times. Because this unit is a compact DIN-rail style module, keeping a verified spare on the shelf is a realistic maintenance strategy. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is the MTL SD32 a genuine MTL unit or a clone?
Autronexa verifies every MTL SD32 against OEM datasheet markings and part-number cross-reference before it enters stock. Units are genuine surplus or professionally refurbished, not grey-market copies.
What condition will the SD32 surge protector arrive in?
The MTL SD32 is supplied as refurbished unless otherwise stated. Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch.
How fast can Autronexa ship the SD32?
Lead time depends on current stock at the time of order. Contact Autronexa with your SD32 requirement for verified condition and current availability.
What are the SD32 voltage and current ratings?
The MTL SD32 is rated for 32 VDC and 22 VAC nominal voltage with a nominal current of 250 mA. Its rated voltage (MCOV) is 36, and the voltage protection level is less than 45 V at 1 kV/µs.
Does the SD32 include a fuse disconnect feature?
Yes. The MTL SD32 includes a fuse disconnect feature, which allows the protected circuit to be isolated during maintenance without removing the module from its mounting.
Related & compatible parts
MTL
MTL5041
Genuine surplus MTL5041 isolator: fully-floating 2-wire transmitter supply with 4 to 20mA repeat for safe-area loads. Verified condition,…
MTL
SD07R
Genuine MTL SD07R surge protector with 50MHz bandwidth. Verified surplus stock, tested and ready for your signal line…
MTL
MTL4016
Genuine surplus MTL4016 interface: two channels, relay outputs, line fault detection, and hazardous-area certification for Zone 0/Div.1.
MTL
SD16R
Genuine MTL SD16R surge protection device with 50MHz bandwidth and <1ns response time. Verified surplus and refurbished units…
News & guides for MTL
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…