MTL SD16
Circuit Protection
Genuine MTL SD16 surge protection module with fuse disconnect, rated 16 Vdc and 250 mA — verified surplus stock ready for your signal loop.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Nominal voltage (Un) | 16 Vdc / 11 Vac |
|---|---|
| Nominal current (In) | 250 mA |
| Series resistance | 4.2 ohms per line |
| Max. leakage current | 5 µA |
| Rated voltage (MCOV) | 17 V |
| Voltage protection level (Up) @1kV/µs | <25 V |
| Residual voltage @isn | 40 V |
| Bandwidth | 25 kHz |
| Special feature | Fuse disconnect |
Description
Industrial signal loops have grown denser and more sensitive with every control-system generation, so a single unprotected pair can now take down more than it once could. The MTL SD16 is a surge protection module built for low-voltage signal circuits, rated at a nominal 16 Vdc and 250 mA, with a fuse disconnect feature that lets technicians isolate a loop without pulling wiring. Maintenance teams and panel builders reach for this model when they need a compact protective barrier that matches the circuit rather than a generic device. Autronexa supplies it as a genuine surplus unit, verified against OEM markings before dispatch.
What the MTL this unit Does in a Signal Circuit
The module sits in series with a signal line and limits what reaches the downstream electronics. Its nominal voltage is 16 Vdc, and the same line lists 11 Vac as an alternating rating, so it suits circuits that carry a low-level DC signal. Nominal current is 250 mA, which covers typical instrumentation loops. Series resistance is given as 4.2 ohms per line, and the maximum leakage current is 5 µA, keeping the protective element from disturbing the measured signal. The voltage protection level is under 25 V at 1 kV/µs, and residual voltage at rated current is 40 V. Bandwidth extends to 25 kHz, so the module passes the signal frequencies these loops normally carry. The fuse disconnect feature is the practical detail many buyers ask about first: it gives a clear isolation point during maintenance.

Why Genuine Surplus Suits This Protection Module
Surge protectors are often treated as consumables, yet the MTL this unit is a specified component with defined electrical values. A refurbished or surplus unit from Autronexa is checked against the OEM datasheet values above and functionally verified before it ships. That matters when a panel is being restored and the original model must be matched rather than substituted. Because these modules are frequently pulled from decommissioned systems, surplus supply can shorten the wait compared with ordering through standard channels. Autronexa keeps genuine parts, verified, in its surplus and refurbished inventory, and the sourcing team can confirm condition and current availability for your exact requirement.

Sourcing Checks Before You Order an this unit
Buyers should confirm the circuit voltage and current against the 16 Vdc and 250 mA ratings, and check that the 4.2 ohms per line series resistance fits the loop budget. The 25 kHz bandwidth should also be compared with the signal frequency in use. Ask for the fuse disconnect variant specifically, since that feature defines this model. Condition should be stated clearly: surplus units are removed from service, while refurbished units are tested. Autronexa can provide verified condition details and current lead time on request. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is the MTL SD16 a genuine module or a copy?
Autronexa verifies each MTL SD16 against OEM datasheet markings and part-number cross-reference before it enters stock. Units are supplied as genuine surplus or refurbished, not as grey-market clones.
What condition will the SD16 arrive in?
The MTL SD16 is supplied as a refurbished or surplus unit, tested against the OEM datasheet values and functionally verified by the Autronexa sourcing team. Condition details are confirmed at the time of your request.
How fast can Autronexa ship the SD16?
Lead time for the MTL SD16 depends on current stock. Contact Autronexa with your part number for verified condition and current availability before placing an order.
What are the SD16 electrical ratings?
The MTL SD16 is rated at a nominal 16 Vdc and 250 mA, with series resistance of 4.2 ohms per line and maximum leakage current of 5 µA. Its voltage protection level is under 25 V at 1 kV/µs, and bandwidth extends to 25 kHz.
Related & compatible parts
MTL
MTL3021
Genuine surplus MTL3021 switch/voltage change module for hazardous-area control, verified condition and practical sourcing support from Autronexa.
MTL
MTL5541
Genuine surplus MTL5541 repeater power supply for 4-20mA transmitters in hazardous areas, with HART support and SIL2 capability.…
MTL
MTL4015
Genuine surplus MTL4015 switch/proximity detector for hazardous areas, with dual relay outputs and verified condition from Autronexa.
MTL
MTL3052
Genuine surplus MTL3052 protection module for MTL800 multiplexer data highways, verified condition and ready to ship from Autronexa.
News & guides for MTL
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…