Number of channels One, fully floating
Input voltage 4 to 12V dc
Signal bandwidth dc to 10kHz
Minimum output voltage [Vin minus (0.25 x current in mA)] V
Input and output circuit ripple <1mA peak-to-peak
Power dissipation within unit 160mW maximum at 12V with 20mA signal
Replaceable fuse 50mA, 5 x 20mm glass to DIN 41571 sht. 2, semi-time-lag (M)
Safety description Terminals 5 & 6: 15V, 100Ω, 150mA, Um = 250V rms or dc; Terminals 6 & 7: 15V, 180Ω, 83.3mA, Um = 250V rms or dc
FM max entity parameters Voc = 15V, Isc = 83.3mA, Ca = 0.75µF, La = 5.2mH
Weight 130g

Description

How do you protect multiplexer data highways and transmitters in hazardous areas without slowing digital signals? The MTL3052 is an intrinsically safe protection module from MTL, built for the MTL800 Series multiplexer systems. It provides IS protection for data highways and transmitters, and Autronexa supplies it as a genuine surplus or refurbished unit with verified condition.

What the MTL3052 Does in an MTL800 System

This unit operates on the same principle as the MTL3042 but at a higher frequency, so it suits digital signals. Its primary role is to provide IS protection for the data highways and transmitters in MTL800 Series multiplexer systems. The module has one fully floating channel. It offers two output circuits: a 15V 180Ω safety description on terminals 6 and 7, and an alternative 15V 100Ω circuit on terminals 5 and 6 for higher loop resistances, such as when surge protectors are fitted. Input voltage ranges from 4 to 12V dc, and signal bandwidth spans dc to 10kHz. The minimum output voltage follows Vin minus (0.25 x current in mA) V, while input and output ripple stays below 1mA peak-to-peak.

Figure 1: Front view of the MTL MTL3052 Protection showing its physical design and enclosure.

Safety Ratings and Installation Notes

The module suits Zone 0, IIC, T4–6 hazardous areas if suitably certified, and Div 1, Group A hazardous locations. When the low-resistance outputs of two unit units are used on a dual-highway system, multiplexer transmitters are restricted to Zone 0, IIB, T4–6 (Div 1, Group C). The FM max entity parameters are Voc = 15V, Isc = 83.3mA, Ca = 0.75µF, and La = 5.2mH. A replaceable 50mA, 5 x 20mm glass fuse to DIN 41571 sht. 2, semi-time-lag (M), protects the unit. Power dissipation is 160mW maximum at 12V with a 20mA signal, and weight is 130g. Always follow the manufacturer’s safety manual for installation and maintenance.

Figure 2: Technical layout and connection details for the MTL MTL3052 Protection.

Why Choose Genuine Surplus for This Module

OEM lead times for legacy protection modules can stall maintenance schedules. Autronexa stocks genuine surplus and refurbished unit units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. This gives you a practical alternative when you need a verified part without waiting on a full OEM order cycle. Because This unit serves MTL800 multiplexer systems that remain in service, sourcing a tested surplus unit helps keep those systems running. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: MTL3052-datasheet.pdf

Frequently asked questions

Is this a genuine MTL MTL3052, or a clone?

Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished MTL3052 modules, not grey-market copies.

What condition will the MTL3052 arrive in?

Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available subject to stock.

How fast can you ship the MTL3052?

Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability.

Does the MTL3052 work with MTL800 Series multiplexer systems?

Yes. The MTL3052 is designed to provide IS protection for data highways and transmitters in MTL800 Series multiplexer systems, with a signal bandwidth of dc to 10kHz for digital signals.

Related & compatible parts

MTL

MTL5541

Genuine surplus MTL5541 repeater power supply for 4-20mA transmitters in hazardous areas, with HART support and SIL2 capability.…

In Stock

MTL

MTL3013

Genuine surplus MTL3013 two-channel switch/proximity detector relay for hazardous-area sensors, verified and ready to ship from Autronexa.

In Stock

MTL

SD16R

Genuine MTL SD16R surge protection device with 50MHz bandwidth and <1ns response time. Verified surplus and refurbished units…

In Stock

MTL

ICC212

Genuine MTL ICC212 repeater power supply and isolating driver with three-port galvanic isolation, verified for smart transmitter loops.

In Stock

News & guides for MTL

View all articles

Request a quote for this part

Part number: MTL3052

We reply within one business day.

MTL3052 Quote reply within 1 business day