MTL I/O & Function Modules

MTL MTL4014

Switch located

Manufacturer: MTL Part Number: MTL4014

Genuine surplus MTL4014 switch input relay for hazardous-area circuits, with line fault detection and 2ms response. Verified condition from Autronexa.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Number of channels One
Location of switch Zone 0, IIC, T6 hazardous area; Div.1, Group A
Voltage applied to sensor 7.0V – 9.0V dc from 1kΩ nominal
Output thresholds Closed if input >2.1mA (<2kΩ); open if input <1.2mA (>10kΩ)
Response time 2ms maximum
Contact rating 10W, 0.5A, 35V (dc)
Isolation 250V ac between safe and hazardous area circuits
Power requirement 45mA at 24V dc; 50mA at 20V dc; 36mA at 35V dc

Description

When a switch in a Zone 0 hazardous area must control a safe-area load, the barrier between those circuits decides whether the signal arrives cleanly. The MTL4014 solves that problem with a single-channel relay that also reports line faults through a separate relay. Autronexa supplies this unit as genuine surplus, verified before dispatch.

What the MTL4014 Does in a Hazardous-Area Circuit

This unit enables a safe-area load to be controlled by a proximity detector or switch located in a hazardous area through a reed relay. Its switch location covers Zone 0, IIC, T6 and Div.1, Group A. The unit applies 7.0V – 9.0V dc to the sensor from a 1kΩ nominal source. Output closes when input exceeds 2.1mA (10kΩ). Hysteresis is 200µA (650Ω) nominal. Line fault detection cannot be disabled, so broken or shorted lines are always reported.

Figure 1: Front view of the MTL MTL4014 Switch located showing its physical design and enclosure.

Technical Specs That Matter on Site

The relay output is single-pole on/off and open when de-energised, with a 2ms maximum response time. Contact rating is 10W, 0.5A, 35V (dc), and contact life expectancy is 107 operations at maximum load. Reactive loads must be adequately suppressed. Isolation is 250V ac between safe and hazardous area circuits. Power requirement is 45mA at 24V dc, 50mA at 20V dc and 36mA at 35V dc. Three LEDs show input, line fault and power status.

Figure 2: Technical layout and connection details for the MTL MTL4014 Switch located.

Why Genuine Surplus Fits This Model

This unit carries a specific safety description of 10.5V, 800Ω, 14mA, so a clone or mislabelled unit is not a practical substitute. Autronexa sources genuine surplus and refurbished units, checks markings and part numbers against the datasheet, and confirms condition before shipping. For maintenance teams, that means a verified replacement without waiting on a full OEM lead time. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: MTL4014-datasheet.pdf

Frequently asked questions

Is this a genuine MTL MTL4014, or a clone?

Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it is listed. The MTL4014 safety description of 10.5V, 800Ω, 14mA is part of that check.

What condition will the MTL4014 arrive in?

Units are supplied as genuine surplus or refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the current condition grading of available stock.

How fast can you ship the MTL4014?

Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability.

Does the MTL4014 work with both proximity detectors and switches?

Yes. The line fault detection function works with both, provided switch-type sensors are fitted with suitable resistors as shown in the circuit diagram. LFD cannot be disabled.

Related & compatible parts

MTL

MTL5541

Genuine surplus MTL5541 repeater power supply for 4-20mA transmitters in hazardous areas, with HART support and SIL2 capability.…

In Stock

MTL

SD32X

Genuine MTL SD32X surge protection device with 32Vdc nominal voltage and 400 mA nominal current. Verified surplus stock…

In Stock

MTL

MTL4706

Genuine surplus MTL4706 barrier for 2-wire transmitters: ±2µA accuracy, 4/20mA output, verified condition and clear lead times from…

In Stock

MTL

MTL3041

Genuine surplus MTL3041 transmitter isolator with fully floating 17.5V loop supply and 4 to 20mA signal range, verified…

In Stock

News & guides for MTL

View all articles

Request a quote for this part

Part number: MTL4014

We reply within one business day.

MTL4014 Quote reply within 1 business day