SICK I/O & Function Modules

SICK DL50-P2228

Switching mode: distance to object

Manufacturer: SICK Part Number: DL50-P2228

Genuine SICK DL50-P2228 distance sensor with 50 m range and 100 µm resolution. Verified surplus and refurbished units ready to ship from Autronexa.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Measuring range 200 mm ... 50,000 mm, on diamond grade reflective tape
Resolution 100 µm
Measurement accuracy ± 3 mm
Response time 10 ms ... 160 ms
Supply voltage DC 10 V ... 30 V
Enclosure rating IP65
Dimensions (W x H x D) 36.1 mm x 62.7 mm x 57.7 mm
Weight 200 g

Description

The SICK DL50-P2228 is a Switching mode: distance to object for industrial control and automation applications.

The SICK DL50-P2228 is a time-of-flight distance sensor with a 200 mm to 50,000 mm measuring range on diamond-grade reflective tape, 100 µm resolution, and ±3 mm accuracy. Maintenance and procurement teams choose genuine surplus or refurbished units to avoid OEM lead times without sacrificing verified performance.

What Does this sensor Measure and How Does It Work?

This sensor uses a visible red laser to measure distance to a target reflector. It operates in distance-to-object (DtO) switching mode, so the digital output changes state based on the measured distance. The sensor delivers a 10 ms to 160 ms response time and a 2.5 ms output time, making it suitable for dynamic positioning tasks. A 15 mm x 15 mm light spot at 10 m keeps the beam well defined over long spans. The laser is Class 1 per IEC 60825-1:2014 and EN 60825-1:2014, with an average service life of 100,000 hours at 25 °C. The zinc diecast housing measures 36.1 mm x 62.7 mm x 57.7 mm and weighs 200 g. The IP65 enclosure rating and –30 °C to +65 °C operating range suit demanding industrial environments.

Figure 1: Front view of the SICK DL50-P2228 Switching mode: distance to object showing its physical design and enclosure.

How Does this sensor Compare with Other Distance Sensors?

When evaluating alternatives, consider these practical differences:

  • Measuring range: this sensor covers 200 mm to 50,000 mm on reflective tape, while many standard photoelectric sensors stop well short of that span.
  • Resolution and accuracy: A 100 µm resolution and ±3 mm accuracy give this model an edge over basic ultrasonic or infrared units in position feedback tasks.
  • Output flexibility: The PNP digital output supports teach-in, scaling, and inversion, plus a selectable hysteresis of 1 mm to 1,000 mm. Comparable sensors often offer fixed switching behavior only.
  • Interface: SSI is available for direct position data, reducing the need for external signal conditioning.
  • Supply voltage: The 10 V to 30 V DC range and ≤2.1 W power consumption fit standard industrial power supplies.

Figure 2: Technical layout and connection details for the SICK DL50-P2228 Switching mode: distance to object.

Why Choose Genuine Surplus or Refurbished for This Sensor?

This sensor is a specialized time-of-flight sensor, and sourcing a new unit from the OEM can involve extended lead times. Autronexa maintains verified surplus and refurbished stock of SICK sensors, including this model. Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team. You get genuine parts, verified, with clear lead times and practical technical support. For maintenance managers, that means less downtime and a lower total cost than buying new. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is the SICK DL50-P2228 a genuine SICK product or a clone?

Autronexa verifies every SICK DL50-P2228 against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished units only, never grey-market copies.

What condition will the DL50-P2228 arrive in?

Our default condition for the SICK DL50-P2228 is refurbished, meaning it has been tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available depending on stock.

How fast can Autronexa ship the SICK DL50-P2228?

Lead time for the SICK DL50-P2228 depends on current stock. Contact Autronexa for verified condition and current availability before ordering.

Does the DL50-P2228 support SSI output?

Yes, the SICK DL50-P2228 supports SSI output as listed in its technical data, along with a PNP digital output for switching tasks.

Related & compatible parts

SICK

BEF-WK-SF

Genuine SICK BEF-WK-SF servo clamp set: three eccentric fastener clamps for servo flanges, supplied without mounting hardware and…

In Stock

SICK

DL100-11AA2101

Genuine surplus SICK DL100-11AA2101 laser distance sensor with 60 m range, 15 m/s tracking, and SSI interface —…

In Stock

SICK

DFS60B-S1MA10000

Genuine SICK DFS60B-S1MA10000 incremental encoder with 10,000 PPR and 6 x 10 mm shaft — verified surplus stock…

In Stock

SICK

BEF-FA-036-100

Genuine SICK BEF-FA-036-100 aluminum flange adapter — verified surplus and refurbished units for 36 mm to 100 mm…

In Stock

News & guides for SICK

View all articles

Request a quote for this part

Part number: DL50-P2228

We reply within one business day.

DL50-P2228 Quote reply within 1 business day