Keyence AP-33K
Digital pressure sensor
Genuine surplus Keyence AP-33K digital pressure sensor — 0–145 PSI, NPN, verified condition and faster lead time than OEM.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated pressure | 0 to 145.0 PSI |
|---|---|
| Detectable pressure range | -15 to +110 % of F.S. |
| Fluid type | Air or non-corrosive gases |
| Output type | NPN open collector, 2-output (N.O./N.C. selectable) |
| Supply voltage | 12 to 24 VDC ±10% |
| Analog output | 1 to 5 V (Load impedance: 47 kΩ minimum) |
| Response time | 2.5 / 5 / 100 / 500 ms selectable |
| Operating temperature | 0 to +50 °C (No freezing) |
| Weight | Approx. 120 g |
Description
How do you keep a pressure-critical line running when a sensor fails and the OEM lead time stretches into weeks? The Keyence AP-33K digital pressure sensor answers that question for maintenance and procurement teams: a positive-pressure, NPN-output unit from the AP-30 series with a 0 to 145.0 PSI rated range, available through Autronexa as verified genuine surplus rather than a long-lead OEM order.
What the AP-30 Series Brings to a Pressure Loop
The AP-30 family is built around fast, readable pressure feedback, and this variant shows it in the display and response settings. The 3½-digit, 2-color, 7-segment LED has an 11 mm character height, so operators can read gauge pressure at a glance from the panel. Resolution reaches 0.2 PSI, 0.001 MPa, 0.01 kgf/cm², and 0.01 bar, which suits leak checks and fine setpoint work on air or non-corrosive gases. Response time is selectable at 2.5 / 5 / 100 / 500 ms, letting you trade speed for chattering prevention where pulsation is present. The display temperature characteristic stays within ±1 % maximum (of F.S.) at 25 °C across the 0 to 50 °C range. Gauge pressure is the measurement type, and the detectable range spans -15 to +110 % of F.S.

Electrical Fit and Output Behavior
The unit runs on 12 to 24 VDC ±10%, drawing 50 mA maximum at 24 V and 90 mA maximum at 12 V. Two NPN open-collector outputs are selectable as N.O. or N.C., rated 100 mA maximum (40 V maximum) with 1 V maximum residual voltage. An analog output of 1 to 5 V is available with a load impedance of 47 kΩ minimum. There are no built-in ports and no communication expansion, so plan this sensor as a discrete and analog device rather than a networked node. The oil-proof cabtyre cable and die-cast zinc pressure port suit typical machine-mounted service, and the polyamide front housing with PET panel sheet and polysulfone rear housing keep the unit at approximately 120 g.

Why Genuine Surplus Fits This Sensor
Keyence lists the AP-33K as active, with production status confirmed on the official product page as of 2026-09. That matters because an active model is exactly where buyers face OEM list pricing and queue time. Autronexa stocks genuine surplus and refurbished units, each tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch. You get the same 0 to 145.0 PSI sensing range and NPN output behavior without paying new-from-OEM pricing or waiting on a factory allocation. For a maintenance team holding a line together, that is the practical difference between a same-week repair and a stalled asset. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Keyence AP-33K, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished Keyence components, not copies.
What condition will the AP-33K arrive in?
Units ship in our default refurbished condition, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade confirmed before ordering.
How fast can you ship the AP-33K?
Lead time depends on current stock. Contact Autronexa for the present availability and dispatch date for this sensor.
Does the AP-33K connect to a PLC or network?
The unit has no built-in communication ports or protocols. It provides two NPN open-collector outputs and a 1 to 5 V analog output, so it wires to discrete and analog inputs rather than a fieldbus.
Is the AP-33K still in production?
Yes. Keyence production status is confirmed on the official product page as of 2026-09. Please verify current lifecycle status and availability with Autronexa before ordering.
Related & compatible parts
Keyence
EH-440
Genuine surplus Keyence EH-440 sensor head — 18 mm stable range, 0.037 mm repeatability, IP67. Verified condition from…
Keyence
GL-R06L
Genuine surplus Keyence GL-R06L Type 4 safety light curtain set, verified and ready to ship.
Keyence
AP-34K
Genuine surplus Keyence AP-34K compound pressure sensor — verified condition, tested against OEM specs, ready to ship.
Keyence
AP-31K
Genuine surplus Keyence AP-31K negative-pressure sensor, verified and ready to ship — a practical alternative to OEM lead…
News & guides for Keyence
Keyence spare parts: buying guide, series overview and how to order
Keyence spare parts buying guide: 5 parts online, popular series, condition options and how our RFQ process works.
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…